Raman sensitivity enhancement for aqueous absorbing sample using Teflon-AF 2400 liquid core optical fibre cell
- PMID: 17386439
- DOI: 10.1016/j.aca.2006.07.082
Raman sensitivity enhancement for aqueous absorbing sample using Teflon-AF 2400 liquid core optical fibre cell
Abstract
The compatibility Teflon-AF 2400 liquid core optical fibre with resonance Raman spectroscopy (RRS-LCOF) was used to detect aqueous biomolecules. The maximum sensitivity enhancement factor for concentrations greater than the detection limit in a conventional cell was 10, and detection limit reduction of about 1000-fold have been achieved for the measurement of aqueous absorbing sample using Teflon-AF 2400 fibre Raman cell compared to the conventional cell. We were able to collect spectra of 2.5 x 10(-9) and 2.5 x 10(-10) M aqueous beta-carotene using 16.2 mW of laser power and 10s integration time. This volume of a 2.5 x 10(-10) M aqueous solution corresponds to only 1.5 fmol or 830 fg of beta-carotene. The results of this preliminary study indicate that RRS-LCOF has potential in bioanalytical and biomedical applications.
Similar articles
-
Quantitative analysis of Raman signal enhancement from aqueous samples in liquid core optical fibers.Appl Spectrosc. 2004 Oct;58(10):1165-71. doi: 10.1366/0003702042336109. Appl Spectrosc. 2004. PMID: 15527516
-
Raman sensitivity enhancement for aqueous protein samples using a liquid-core optical-fiber cell.Anal Chem. 2001 Mar 15;73(6):1393-7. doi: 10.1021/ac001220y. Anal Chem. 2001. PMID: 11305681
-
Quantitative concentration measurements of creatinine dissolved in water and urine using Raman spectroscopy and a liquid core optical fiber.J Biomed Opt. 2005 May-Jun;10(3):031115. doi: 10.1117/1.1917842. J Biomed Opt. 2005. PMID: 16229640
-
Achievements in resonance Raman spectroscopy review of a technique with a distinct analytical chemistry potential.Anal Chim Acta. 2008 Jan 14;606(2):119-34. doi: 10.1016/j.aca.2007.11.006. Epub 2007 Nov 9. Anal Chim Acta. 2008. PMID: 18082644 Review.
-
New trends in telescopic remote Raman spectroscopic instrumentation.Spectrochim Acta A Mol Biomol Spectrosc. 2007 Dec 15;68(4):1008-22. doi: 10.1016/j.saa.2007.06.047. Epub 2007 Aug 2. Spectrochim Acta A Mol Biomol Spectrosc. 2007. PMID: 17723317 Review.
Cited by
-
Aerogel-Lined Capillaries as Liquid-Core Waveguides for Raman Signal Gain of Aqueous Samples: Advanced Manufacturing and Performance Characterization.Sensors (Basel). 2024 Sep 14;24(18):5979. doi: 10.3390/s24185979. Sensors (Basel). 2024. PMID: 39338724 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources