Flow injection chemiluminescence determination of nitrofurazone in pharmaceutical preparations and biological fluids based on oxidation by singlet oxygen generated in N-bromosuccinimide-hydrogen peroxide reaction
- PMID: 17386480
- DOI: 10.1016/j.aca.2006.08.058
Flow injection chemiluminescence determination of nitrofurazone in pharmaceutical preparations and biological fluids based on oxidation by singlet oxygen generated in N-bromosuccinimide-hydrogen peroxide reaction
Abstract
A simple flow injection chemiluminescence (FI-CL) method was proposed for the determination of nitrofurazone. Strong CL signal was generated during the reaction of nitrofurazone with H(2)O(2) and N-bromosuccinimide (NBS) in alkaline condition. The CL signal was proportional to the nitrofurazone concentration in the range 1.0 x 10(-7) to 1.0 x 10(-5) g mL(-1). The detection limit was 2 x 10(-8) g mL(-1) nitrofurazone and the relative standard deviation was less than 4% (6.0 x 10(-6) g mL(-1) nitrofurazone, n=11). The proposed method was successfully applied to the determination of nitrofurazone in compound furacillin nasal drops, human plasma and urine samples. The CL reaction mechanism was also discussed briefly. Singlet oxygen generated in the reaction between H(2)O(2) and NBS was suggested to be participated in the CL reaction.
Similar articles
-
Flow injection chemiluminescence determination of imipramine in tablets, human plasma and urine samples based upon oxidation with singlet oxygen generated in N-bromosuccinimide-hydrogen peroxide reaction.Anal Sci. 2007 May;23(5):597-600. doi: 10.2116/analsci.23.597. Anal Sci. 2007. PMID: 17495408
-
Flow-injection chemiluminescence determination of diazepam by oxidation with N-bromosuccinimide.Luminescence. 2013 Nov-Dec;28(6):888-93. doi: 10.1002/bio.2452. Epub 2012 Nov 23. Luminescence. 2013. PMID: 23175271
-
Ultrasensitive assay of clindamycin in medicine and bio-fluids with chemiluminescence detection.Luminescence. 2007 Nov-Dec;22(6):534-9. doi: 10.1002/bio.996. Luminescence. 2007. PMID: 17768707
-
[Recent progress in flow-injection chemiluminescence for pharmaceutical analysis].Guang Pu Xue Yu Guang Pu Fen Xi. 2006 May;26(5):816-20. Guang Pu Xue Yu Guang Pu Fen Xi. 2006. PMID: 16883844 Review. Chinese.
-
Analytical applications of flow injection with chemiluminescence detection--a review.Luminescence. 2001 Jan-Feb;16(1):1-23. doi: 10.1002/bio.607. Luminescence. 2001. PMID: 11180653 Review.
Cited by
-
A simple and sensitive spectrofluorimetric method for analysis of some nitrofuran drugs in pharmaceutical preparations.J Fluoresc. 2008 Sep;18(5):771-80. doi: 10.1007/s10895-008-0323-4. Epub 2008 Feb 1. J Fluoresc. 2008. PMID: 18246413
-
Paper-based Chemiluminescence Device with Co-Fe Nanocubes for Sensitive Detection of Caffeic Acid.Anal Sci. 2021 Feb 10;37(2):293-299. doi: 10.2116/analsci.20P229. Epub 2020 Aug 28. Anal Sci. 2021. PMID: 32863334
-
Silver nanopopcorns decorated on flexible membrane for SERS detection of nitrofurazone.Mikrochim Acta. 2024 May 28;191(6):347. doi: 10.1007/s00604-024-06421-1. Mikrochim Acta. 2024. PMID: 38802574
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous