Improving the sensitivity of the determination of ceftiofur by capillary electrophoresis in environmental water samples: in-line solid phase extraction and sample stacking techniques
- PMID: 17386775
- DOI: 10.1016/j.aca.2007.01.043
Improving the sensitivity of the determination of ceftiofur by capillary electrophoresis in environmental water samples: in-line solid phase extraction and sample stacking techniques
Abstract
This paper describes two different approaches for increasing the sensitivity for the analysis of ceftiofur by capillary electrophoresis (CE). Two different techniques based on the introduction of an enlarged volume of sample, namely large volume sample stacking (LVSS) and in-line solid phase extraction (SPE) were studied and compared. LVSS allowed the on-column electrophoretic preconcentration of ceftiofur without modification of the separation capillary. In-line SPE-CE was developed by using a home-made microcartridge that was filled with a reversed-phase sorbent (C(18)). The microcartridge was coupled in-line near the inlet of the separation capillary. LVSS and in-line SPE-CE allowed automated operation and improved sensitivity for the analysis of ceftiofur with respect to conventional CE. When environmental water samples were analyzed, an additional pretreatment step based on off-line SPE was necessary in both cases to further decrease the detection limits. In terms of sensitivity for the determination of ceftiofur in river water samples, the combination of off-line SPE with in-line SPE-CE was found the most sensitive with a detection limit of 10 ng L(-1), whereas the method based on the use of off-line SPE with LVSS presented a detection limit of 100 ng L(-1).
Similar articles
-
Use of large-volume sample stacking in on-line solid-phase extraction-capillary electrophoresis for improved sensitivity.Electrophoresis. 2008 Mar;29(6):1339-46. doi: 10.1002/elps.200700636. Electrophoresis. 2008. PMID: 18288781
-
Sensitivity enhancement for the analysis of naproxen in tap water by solid-phase extraction coupled in-line to capillary electrophoresis.J Sep Sci. 2008 Mar;31(5):872-80. doi: 10.1002/jssc.200700593. J Sep Sci. 2008. PMID: 18275109
-
Trace determination of beta-lactam antibiotics in environmental aqueous samples using off-line and on-line preconcentration in capillary electrophoresis.J Chromatogr A. 2008 Mar 28;1185(2):273-80. doi: 10.1016/j.chroma.2007.12.088. Epub 2008 Jan 12. J Chromatogr A. 2008. PMID: 18295774
-
Sorbent preconcentration procedures coupled to capillary electrophoresis for environmental and biological applications.Anal Chim Acta. 2008 May 26;616(1):1-18. doi: 10.1016/j.aca.2008.03.062. Epub 2008 Apr 7. Anal Chim Acta. 2008. PMID: 18471478 Review.
-
Advantages and limitations of on-line solid phase extraction coupled to liquid chromatography-mass spectrometry technologies versus biosensors for monitoring of emerging contaminants in water.J Chromatogr A. 2007 Jun 8;1152(1-2):97-115. doi: 10.1016/j.chroma.2007.01.046. Epub 2007 Jan 18. J Chromatogr A. 2007. PMID: 17275010 Review.
Cited by
-
Solvent-Based and Matrix-Matched Calibration Methods on Analysis of Ceftiofur Residues in Milk and Pharmaceutical Samples Using a Novel HPLC Method.Vet Med Sci. 2024 Nov;10(6):e70080. doi: 10.1002/vms3.70080. Vet Med Sci. 2024. PMID: 39422084 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources