. 2007 Jul;18(7):1423-32.
doi: 10.1007/s10856-007-0148-8. Epub 2007 Mar 27.

In vitro study of drug-eluting stent coatings based on poly(L-lactide) incorporating cyclosporine A - drug release, polymer degradation and mechanical integrity

Affiliations

In vitro study of drug-eluting stent coatings based on poly(L-lactide) incorporating cyclosporine A - drug release, polymer degradation and mechanical integrity

Katrin Sternberg et al. J Mater Sci Mater Med. 2007 Jul.

Abstract

In this study, absorbable polymer stent coatings for localized drug delivery based on poly(L-lactide) (PLLA) and cyclosporine A (CsA) were developed and tested in vitro. Metallic stents were coated with different compositions of PLLA/CsA (70/30, 60/40, 50/50% w/w) and beta-sterilized. The specimens were used to assess the drug release kinetics with HPLC. Sterilization influenced polymer degradation was measured with GPC. Mechanical integrity of the stent coatings was studied with SEM. The interconnection of the coated stents with a balloon-catheter was characterized by the measurement of stent dislodgment force. A migration assay was used to determine the inhibitory effect of the model drug CsA on smooth muscle cell (SMC) migration. The release of CsA was established over time periods up to 24 days in sodium chloride solution and in porcine blood plasma. An inhibition of SMC migration (max. 26-33%) was found for CsA concentrations of 4 x 10(-5) to 4 x 10(-7) mol/l. Marked molecular weight reduction (70-80%) of the PLLA matrix occurred after beta-sterilization. We also observed a substantial decrease of in vitro degradation time. The maintenance of the mechanical integrity of the polymer coating during crimping and dilation of the specimens could be verified, and a sufficient stent dislodgment force of 0.8-0.9 N was measured.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Endourol. 2002 Dec;16(10 ):759-62 - PubMed
    1. Circulation. 1996 Jul 1;94(1):35-43 - PubMed
    1. J Interv Cardiol. 1995 Aug;8(4):395-405 - PubMed
    1. Biomaterials. 1992;13(3):176-82 - PubMed
    1. J Microencapsul. 2003 Nov-Dec;20(6):731-43 - PubMed

Publication types

MeSH terms

LinkOut - more resources