Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Sep;127(7):531-5.
doi: 10.1007/s00402-007-0313-z. Epub 2007 Mar 31.

Minimally invasive plating for complex humeral shaft fractures

Affiliations

Minimally invasive plating for complex humeral shaft fractures

Rui Jiang et al. Arch Orthop Trauma Surg. 2007 Sep.

Abstract

Introduction: The treatment for humeral shaft fracture is still controversial, especially for complex fractures. The purpose of this study was to evaluate the clinical and radiographic outcomes of treating complex humeral shaft fractures by using locking compression plate with minimally invasive technique.

Materials and methods: A total of 21 patients with 21 acute complex humeral shaft fractures (AO type C) were included in this study. All were treated with locking compression plate in a minimally invasive way. The average age of the patients was 42.9 years and there were 14 males and 7 females. Plain radiographs of humerus were used to assess bony union. Functional recovery of the shoulder joint was assessed using the Constant and HSS scoring systems.

Results: The patients were followed for a mean of 28.7 months (range 19-37). With one operation, nineteen fractures (90.4%) achieved a solid union in an average of 14.3 weeks. At final follow-up, 20 patients (95.2%) had satisfactory alignment, except for one associated with olecranon fracture, all patients had a good to excellent elbow function with a mean HSS score of 91.7 points. Eighteen patients (85.7%) achieved satisfactory shoulder function with a mean Constant score of 83.1 points. One superficial infection (4.8%) and two non-unions (9.6%) were found postoperatively.

Conclusions: It was concluded that use of a minimally invasive plate osteosynthesis with locking compression plate is a safe alternative way to classic surgical methods in the treatment of complex humeral shaft fractures, which had a high union rate with less risk of complications.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources