Amperometric L-lactate sensor based on sol-gel processing of an enzyme-linked silicon alkoxide
- PMID: 17417817
- DOI: 10.1021/ac061972d
Amperometric L-lactate sensor based on sol-gel processing of an enzyme-linked silicon alkoxide
Abstract
A novel organically modified silica material has been prepared by covalent linking of the carboxylic acid group of lactate dehydrogenase to the amino group of an organoalkoxysilane precursor via a carbodiimide coupling reaction during the sol-gel process. The material was used to fabricate a leak-free biosensor. The experimental variables and characteristics of the biosensors were studied by electrochemical methods. Results showed that the coenzyme concentration, mediator concentration, and electrode rotation speed will influence the sensitivity of the biosensor. The biosensors exhibited high sensitivity (1.47 microA/mM), low detection limit (1.5 microM), reasonable apparent activity (1.31 min(-1)), good fabrication reproducibility, and good long-term operational stability (approximately 1 week).
Similar articles
-
A lactate biosensor based on lactate dehydrogenase/nictotinamide adenine dinucleotide (oxidized form) immobilized on a conducting polymer/multiwall carbon nanotube composite film.Anal Biochem. 2009 Jan 1;384(1):159-65. doi: 10.1016/j.ab.2008.09.030. Epub 2008 Sep 25. Anal Biochem. 2009. PMID: 18851940
-
Evaluation of different strategies for the development of amperometric biosensors for L-lactate.Biosens Bioelectron. 2007 May 15;22(11):2663-8. doi: 10.1016/j.bios.2006.10.034. Epub 2006 Dec 1. Biosens Bioelectron. 2007. PMID: 17141496
-
Direct electrochemistry of lactate dehydrogenase immobilized on silica sol-gel modified gold electrode and its application.Biosens Bioelectron. 2007 Dec 15;23(5):682-7. doi: 10.1016/j.bios.2007.08.002. Epub 2007 Aug 10. Biosens Bioelectron. 2007. PMID: 17869089
-
The potential of biosensor technology in clinical monitoring and experimental research.Biomed Mater Eng. 2004;14(4):455-64. Biomed Mater Eng. 2004. PMID: 15472394 Review.
-
Entrapment of biomolecules in sol-gel matrix for applications in biosensors: problems and future prospects.Biosens Bioelectron. 2007 May 15;22(11):2387-99. doi: 10.1016/j.bios.2006.12.025. Epub 2007 Jan 5. Biosens Bioelectron. 2007. PMID: 17291744 Review.
Cited by
-
Electrochemical sensors.Anal Chem. 2008 Jun 15;80(12):4499-517. doi: 10.1021/ac8007219. Epub 2008 May 21. Anal Chem. 2008. PMID: 18491869 Free PMC article. Review. No abstract available.
-
Biosensors based on electrochemical lactate detection: A comprehensive review.Biochem Biophys Rep. 2015 Nov 11;5:35-54. doi: 10.1016/j.bbrep.2015.11.010. eCollection 2016 Mar. Biochem Biophys Rep. 2015. PMID: 28955805 Free PMC article. Review.
-
Electrochemical Sensors for Clinic Analysis.Sensors (Basel). 2008 Mar 27;8(4):2043-2081. doi: 10.3390/s8042043. Sensors (Basel). 2008. PMID: 27879810 Free PMC article. Review.
-
Enzyme-coated microelectrodes to monitor lactate production in a nanoliter microfluidic cell culture device.Biosens Bioelectron. 2010 Oct 15;26(2):828-33. doi: 10.1016/j.bios.2010.05.030. Epub 2010 Jun 2. Biosens Bioelectron. 2010. PMID: 20566279 Free PMC article.
-
BioMEMS -Advancing the Frontiers of Medicine.Sensors (Basel). 2008 Sep 26;8(9):6077-6107. doi: 10.3390/s8096077. Sensors (Basel). 2008. PMID: 27873858 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous