Monte Carlo-based calculation of imaging plate response to (90)Sr in teeth: experimental validation of the required correction on sample thickness

Affiliations

Monte Carlo-based calculation of imaging plate response to (90)Sr in teeth: experimental validation of the required correction on sample thickness

Kenichi Tanaka et al. Radiat Environ Biophys. 2007 Aug.

Abstract

Recently, a numerical method was proposed to correct the imaging plate (IP) response to (90)Sr concentration in tooth samples, depending on the sample thickness. This is important to quantify any (90)Sr concentration in teeth, which in turn is necessary to determine any (90)Sr incorporation of a person retrospectively. Although the final goal will be to evaluate the (inhomogeneous) spatial distribution of (90)Sr inside tooth samples precisely, the present study was restricted -- as a first step -- to the evaluation of (90)Sr in teeth assuming a uniform (90)Sr distribution. A numerical method proposed earlier was validated experimentally in the present study by measuring the IP response to standard sources of various thicknesses and (90)Sr concentrations. For comparison, the energy deposition of the beta-rays emitted by (90)Sr in the IP -- which is considered to be proportional to the IP luminescence signal -- was calculated for the various sample thicknesses involved, by means of the MCNP-4C code. As a result, the measured IP response could be reproduced by the calculations within the uncertainties, depending on the thickness of the standard sources. Thus, the validity of the proposed numerical method to correct the IP response for sample thickness has successfully been demonstrated.

PubMed Disclaimer

References

    1. Radiat Res. 2002 Mar;157(3):341-9 - PubMed
    1. Sci Total Environ. 1994 Oct 28;155(3):215-9 - PubMed
    1. Sci Total Environ. 1994 Mar 1;142(1-2):63-72 - PubMed
    1. Health Phys. 2003 Jun;84(6):718-25 - PubMed
    1. J Radiat Res. 2006 Feb;47 Suppl A:A81-3 - PubMed

Publication types

Substances

LinkOut - more resources