Corneal refractive therapy with different lens materials, part 1: corneal, stromal, and epithelial thickness changes
- PMID: 17435518
- DOI: 10.1097/OPX.0b013e318042af1d
Corneal refractive therapy with different lens materials, part 1: corneal, stromal, and epithelial thickness changes
Abstract
Purpose: To assess the corneal swelling response to two myopic correction corneal refractive therapy (CRT) lenses of varying Dk/t values, worn for a single night. Change in thickness of the total cornea, stroma, and epithelium was measured across the horizontal meridian using optical coherence tomography (OCT).
Methods: In this double-masked, randomized study, twenty subjects wore a CRT design lens in each eye, manufactured from Menicon Z (MenZ; Dk/t = 91) and Equalens II (EqII; Dk/t = 47) materials. Baseline corneal thickness was measured centrally and at four points either side of the central cornea using OCT, the night before sleeping at the Centre for Contact Lens Research. The next morning, lenses were removed, and thickness measurements were repeated 1, 3, 6, and 12 h after removal.
Results: On lens removal, the MenZ eye had central and paracentral corneal swelling (mean +/- SD) of 4.1 +/- 2.0% and 5.6 +/- 2.4%, and the EqII eye had 5.8 +/- 2.6% and 7.0 +/- 2.6%. These values were significantly different from baseline (ReANOVA; p < 0.001) and were different between lens materials (p < 0.001). The central epithelium thinned by 10.0 +/- 4.5% in the MenZ eye and by 10.2 +/- 8.5% in the EqII eye, with the mid-peripheral epithelium thickening by 13.4 +/- 7.9% in the MenZ eye and 18.3 +/- 9.8% in the EqII eye (all changes different from baseline p < 0.001). These epithelial values were not statistically different between materials (p > 0.05). Stromal swelling values on lens removal were 5.7 +/- 2.2% centrally and 5.5 +/- 3.0% mid-peripherally (MenZ) and 7.7 +/- 3.1% centrally and 6.6 +/- 2.9% mid-peripherally (EqII) (all p < 0.001 from baseline). Central stromal swelling was different between eyes at lens removal (p < 0.001). Stromal thickness in both eyes returned to baseline values within 3 h.
Conclusion: The higher-Dk/t MenZ material caused significantly less overnight corneal and stromal swelling than the Eqll material, which reinforces the need to prescribe lenses with high Dk/t for overnight wear. Neither central epithelial thinning nor paracentral thickening are significantly affected by Dk/t.
Similar articles
-
Corneal refractive therapy with different lens materials, part 2: effect of oxygen transmissibility on corneal shape and optical characteristics.Optom Vis Sci. 2007 Apr;84(4):349-56. doi: 10.1097/OPX.0b013e3180437e6e. Optom Vis Sci. 2007. PMID: 17435519 Clinical Trial.
-
Malleability of the ocular surface in response to mechanical stress induced by orthokeratology contact lenses.Cornea. 2008 Feb;27(2):133-41. doi: 10.1097/ICO.0b013e318158b4b5. Cornea. 2008. PMID: 18216565
-
Overnight orthokeratology lens wear can inhibit the central stromal edema response.Invest Ophthalmol Vis Sci. 2005 Jul;46(7):2334-40. doi: 10.1167/iovs.04-1162. Invest Ophthalmol Vis Sci. 2005. PMID: 15980219
-
Contact lens-induced changes in the anterior eye as observed in vivo with the confocal microscope.Prog Retin Eye Res. 2007 Jul;26(4):398-436. doi: 10.1016/j.preteyeres.2007.03.003. Epub 2007 Apr 1. Prog Retin Eye Res. 2007. PMID: 17498998 Review.
-
Central Corneal Edema with Scleral-Lens Wear.Curr Eye Res. 2018 Nov;43(11):1305-1315. doi: 10.1080/02713683.2018.1500610. Epub 2018 Aug 6. Curr Eye Res. 2018. PMID: 30015536 Review.
Cited by
-
Epithelial and stromal thickness profile and lens decentration in myopic orthokeratology.J Optom. 2023 Oct 28;17(2):100485. doi: 10.1016/j.optom.2023.100485. Online ahead of print. J Optom. 2023. PMID: 39491276 Free PMC article.
-
Short-term changes in light distortion in orthokeratology subjects.Biomed Res Int. 2015;2015:278425. doi: 10.1155/2015/278425. Epub 2015 Jan 28. Biomed Res Int. 2015. PMID: 25699265 Free PMC article.
-
Overnight corneal swelling with high and low powered silicone hydrogel lenses.J Optom. 2015 Jan-Mar;8(1):19-26. doi: 10.1016/j.optom.2014.03.002. Epub 2014 Apr 24. J Optom. 2015. PMID: 25649637 Free PMC article. Clinical Trial.
-
Association between long-term orthokeratology responses and corneal biomechanics.Sci Rep. 2019 Aug 29;9(1):12566. doi: 10.1038/s41598-019-49041-z. Sci Rep. 2019. PMID: 31467346 Free PMC article.
-
The relationship between corneal biomechanics and anterior segment parameters in the early stage of orthokeratology: A pilot study.Medicine (Baltimore). 2017 May;96(19):e6907. doi: 10.1097/MD.0000000000006907. Medicine (Baltimore). 2017. PMID: 28489806 Free PMC article.