Bactericidal action of positive and negative ions in air
- PMID: 17439657
- PMCID: PMC1868029
- DOI: 10.1186/1471-2180-7-32
Bactericidal action of positive and negative ions in air
Abstract
Background: In recent years there has been renewed interest in the use of air ionisers to control of the spread of airborne infection. One characteristic of air ions which has been widely reported is their apparent biocidal action. However, whilst the body of evidence suggests a biocidal effect in the presence of air ions the physical and biological mechanisms involved remain unclear. In particular, it is not clear which of several possible mechanisms of electrical origin (i.e. the action of the ions, the production of ozone, or the action of the electric field) are responsible for cell death. A study was therefore undertaken to clarify this issue and to determine the physical mechanisms associated with microbial cell death.
Results: In the study seven bacterial species (Staphylococcus aureus, Mycobacterium parafortuitum, Pseudomonas aeruginosa, Acinetobacter baumanii, Burkholderia cenocepacia, Bacillus subtilis and Serratia marcescens) were exposed to both positive and negative ions in the presence of air. In order to distinguish between effects arising from: (i) the action of the air ions; (ii) the action of the electric field, and (iii) the action of ozone, two interventions were made. The first intervention involved placing a thin mica sheet between the ionisation source and the bacteria, directly over the agar plates. This intervention, while leaving the electric field unaltered, prevented the air ions from reaching the microbial samples. In addition, the mica plate prevented ozone produced from reaching the bacteria. The second intervention involved placing an earthed wire mesh directly above the agar plates. This prevented both the electric field and the air ions from impacting on the bacteria, while allowing any ozone present to reach the agar plate. With the exception of Mycobacterium parafortuitum, the principal cause of cell death amongst the bacteria studied was exposure to ozone, with electroporation playing a secondary role. However in the case of Mycobacterium parafortuitum, electroporation resulting from exposure to the electric field appears to have been the principal cause of cell inactivation.
Conclusion: The results of the study suggest that the bactericidal action attributed to negative air ions by previous researchers may have been overestimated.
Figures





Similar articles
-
The bactericidal effect of an ionizer under low concentration of ozone.BMC Microbiol. 2016 Jul 30;16(1):173. doi: 10.1186/s12866-016-0785-5. BMC Microbiol. 2016. PMID: 27475908 Free PMC article.
-
[Effects of ionization of the air on some bacterial strains].Ann Ig. 1989 Nov-Dec;1(6):1491-500. Ann Ig. 1989. PMID: 2484482 Italian.
-
[Analysis of bactericidal material generated by electrical devices advertising bactericidal ability against bacteria on the agar gel plates].Kansenshogaku Zasshi. 2012 Nov;86(6):723-33. doi: 10.11150/kansenshogakuzasshi.86.723. Kansenshogaku Zasshi. 2012. PMID: 23367847 Japanese.
-
Air ionization: an evaluation of its physiological and psychological effects.Ann Occup Hyg. 1982;25(4):409-19. doi: 10.1093/annhyg/25.4.409. Ann Occup Hyg. 1982. PMID: 6762130 Review. No abstract available.
-
Biological effects of small air ions: a review of findings and methods.Environ Res. 1984 Aug;34(2):351-89. doi: 10.1016/0013-9351(84)90104-x. Environ Res. 1984. PMID: 6378618 Review.
Cited by
-
Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment.BMC Infect Dis. 2010 Apr 12;10:92. doi: 10.1186/1471-2334-10-92. BMC Infect Dis. 2010. PMID: 20384999 Free PMC article.
-
Numerical and experimental study on airborne disinfection by negative ions in air duct flow.Build Environ. 2018 Jan;127:204-210. doi: 10.1016/j.buildenv.2017.11.006. Epub 2017 Nov 6. Build Environ. 2018. PMID: 32287975 Free PMC article.
-
The bactericidal effect of an ionizer under low concentration of ozone.BMC Microbiol. 2016 Jul 30;16(1):173. doi: 10.1186/s12866-016-0785-5. BMC Microbiol. 2016. PMID: 27475908 Free PMC article.
-
Positive and Negative Ions Potently Inhibit the Viability of Airborne Gram-Positive and Gram-Negative Bacteria.Microbiol Spectr. 2021 Dec 22;9(3):e0065121. doi: 10.1128/Spectrum.00651-21. Epub 2021 Nov 10. Microbiol Spectr. 2021. PMID: 34756075 Free PMC article.
-
Perspective paper: assessing air quality as part of a physical therapy plan of care.Cardiopulm Phys Ther J. 2011 Mar;22(1):20-4. Cardiopulm Phys Ther J. 2011. PMID: 21448345 Free PMC article.
References
-
- Kerr KG, Beggs CB, Dean SG, Thornton J, Donnelly JK, Todd NJ, Sleigh PA, Qureshi A, Taylor CC. Air ionisation and colonisation/infection with methicillin-resistant Staphylococcus aureus and Acinetobacter species in an intensive care unit. Intensive Care Med. 2006;32:315–317. doi: 10.1007/s00134-005-0002-8. - DOI - PubMed
-
- Pratt R, Barnard RW. Some effects of ionized air on Penicillium notatum. J Am Pharm Assoc Sci. 1960;49:643–646.
-
- Furst R. Annual Report. Houston , Anderson Hospital, Houston University of Texas; 1955. Studies on ionization effects .
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical