Clinical utility of a colorimetric end-tidal CO2 detector in cardiopulmonary resuscitation and emergency intubation
- PMID: 1744672
- DOI: 10.1007/BF01619347
Clinical utility of a colorimetric end-tidal CO2 detector in cardiopulmonary resuscitation and emergency intubation
Abstract
The purposes of this study were to evaluate the clinical utility of a colorimetric end-tidal CO2 (ETCO2) detector in confirming proper endotracheal intubation in patients requiring emergency intubation, to determine if this new device can be used as an adjunct to judge the effectiveness of cardiopulmonary resuscitation (CPR), and to determine whether the device can predict successful resuscitation from cardiopulmonary arrest. We studied prospectively 110 patients requiring emergency intubation for either respiratory distress (53 patients) or cardiopulmonary arrest (57 patients) by recording the color range of the indicator after the initial intubation. In patients who suffered a cardiopulmonary arrest, the color range was also recorded during CPR after the endotracheal tube was confirmed to be in the tracheal position and perfusion optimized, and at the moment CPR was stopped. The ETCO2 detector was 100% specific for correct endotracheal intubation in all patients. It was also highly sensitive (0.98) for correct endotracheal intubation in patients with respiratory distress. However, it was not sensitive (0.62) in patients with cardiopulmonary arrest and low perfusion. The sensitivity improved (0.88) when we used the ETCO2 range obtained after attempts to increase perfusion. A low ETCO2 color range in 19 patients undergoing CPR was interpreted as low cardiac output and prompted the physicians to attempt to increase perfusion. Of the patients who underwent CPR, no patient whose ETCO2 level remained less than 2% was successfully resuscitated. Those patients who had an ETCO2 level greater than or equal to 2% had a significantly higher incidence of successful resuscitation.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device.Ann Emerg Med. 1992 May;21(5):518-23. doi: 10.1016/s0196-0644(05)82517-x. Ann Emerg Med. 1992. PMID: 1570906 Clinical Trial.
-
Evaluation of an end-tidal CO2 detector during pediatric cardiopulmonary resuscitation.Pediatrics. 1995 Mar;95(3):395-9. Pediatrics. 1995. PMID: 7862479
-
Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation.Ann Emerg Med. 1996 May;27(5):595-9. doi: 10.1016/s0196-0644(96)70162-2. Ann Emerg Med. 1996. PMID: 8629780 Clinical Trial.
-
Capnography during cardiac arrest.Resuscitation. 2018 Nov;132:73-77. doi: 10.1016/j.resuscitation.2018.08.018. Epub 2018 Aug 22. Resuscitation. 2018. PMID: 30142399 Review.
-
End-tidal carbon dioxide monitoring in the prehospital setting.Prehosp Emerg Care. 2001 Apr-Jun;5(2):208-13. doi: 10.1080/10903120190940146. Prehosp Emerg Care. 2001. PMID: 11339734 Review.
Cited by
-
Comparison of end-tidal CO2 measured by transportable capnometer (EMMA™ capnograph) and arterial pCO2 in general anesthesia.J Clin Monit Comput. 2016 Oct;30(5):737-41. doi: 10.1007/s10877-015-9748-x. Epub 2015 Aug 12. J Clin Monit Comput. 2016. PMID: 26264607
-
Are carbon dioxide detectors useful in neonates?Arch Dis Child Fetal Neonatal Ed. 2006 Jul;91(4):F295-8. doi: 10.1136/adc.2005.082008. Arch Dis Child Fetal Neonatal Ed. 2006. PMID: 16790735 Free PMC article. Review.
-
Breath Biomarkers in Diagnostic Applications.Molecules. 2021 Sep 11;26(18):5514. doi: 10.3390/molecules26185514. Molecules. 2021. PMID: 34576985 Free PMC article. Review.
-
Preventing unrecognized esophageal intubation in the emergency department.J Am Coll Emerg Physicians Open. 2023 Apr 29;4(3):e12951. doi: 10.1002/emp2.12951. eCollection 2023 Jun. J Am Coll Emerg Physicians Open. 2023. PMID: 37128296 Free PMC article.
-
Combined use of the esophageal-tracheal Combitube with a colorimetric carbon dioxide detector for emergency intubation/ventilation.J Clin Monit. 1995 Sep;11(5):311-6. doi: 10.1007/BF01616989. J Clin Monit. 1995. PMID: 7595687