Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Jul;293(1):H735-42.
doi: 10.1152/ajpheart.00168.2007. Epub 2007 Apr 20.

Speckle-tracking strain echocardiography for detecting cardiac dyssynchrony in a canine model of dyssynchrony and heart failure

Affiliations
Free article

Speckle-tracking strain echocardiography for detecting cardiac dyssynchrony in a canine model of dyssynchrony and heart failure

Takeshi Arita et al. Am J Physiol Heart Circ Physiol. 2007 Jul.
Free article

Abstract

Multiple echocardiographic criteria have been proposed to diagnose mechanical dyssynchrony in patients with heart failure without being validated against a model of cardiac dyssynchrony with heart failure. This study examines which of these methods can detect dyssynchrony in a canine model. Adult mongrel dogs underwent His-bundle ablation and right-ventricular pacing for 4 wk at either 110 bpm to induce dyssynchrony without heart failure (D group, n = 12) or 170 bpm to induce dyssynchrony with heart failure (DHF group, n = 9). To induce heart failure with narrow QRS, atria were paced at 190 bpm for 4 wk (HF group, n = 8). Tissue Doppler imaging (TDI) and two-dimensional echocardiography were performed at baseline and at end of study. Standard deviation of time to peak systolic velocity (color-coded TDI), time to peak S wave on pulse-wave TDI, time to peak radial and circumferential strain by speckle-tracking analysis (E(rr) and E(cc), respectively), and septal-to-posterior wall motion delay on M mode were obtained. In D group, only E(rr) and E(cc) were increased by dyssynchrony. In contrast, all the echocardiographic parameters of dyssynchrony appeared significantly augmented in the DHF group. Receiver-operator curve analysis showed good sensitivity of E(rr) (90%) and E(cc) (100%) to detected dyssynchrony without heart failure and excellent sensitivity and specificity of E(rr) and E(cc) to detect dyssynchrony with heart failure. Radial strain by speckle tracking is more accurate than TDI velocity to detect cardiac dyssynchrony in a canine model of dyssynchrony with or without heart failure.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources