Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload
- PMID: 17456489
- DOI: 10.1093/bja/aem062
Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload
Abstract
Background: Left ventricular stroke volume variation (SVV) or its surrogates are useful tools to assess fluid responsiveness in mechanically ventilated patients. So far it is unknown, how changes in cardiac afterload affect SVV. Therefore, this study compared left ventricular SVV derived by pulse contour analysis with SVV measured using an ultrasonic flow probe and investigated the influence of cardiac afterload on left ventricular SVV.
Methods: In 13 anaesthetized, mechanically ventilated pigs [31(SD 6) kg], we compared cardiac output (CO), stroke volume (SV), and SVV determined by pulse contour analysis and by an ultrasonic aortic flow signal (Bland-Altman analysis). After obtaining baseline measurements, cardiac afterload was increased using phenylephrine and decreased using adenosine (both continuously administered). Measurements were performed with a constant tidal volume (12 ml kg-1) without PEEP.
Results: Neither increasing mean arterial pressure (MAP) [from 59 (7) to 116 (19)] nor decreasing MAP [from 63 (7) to 39 (4)] affected CO, SV, and SVV (both methods). Method comparison revealed a bias for SVV of 0.1% [standard error of the mean (SE) 0.8] at baseline, -1.2% (SE 0.8) during decreased and 4.0% (SE 0.7) during increased afterload, the latter being significantly different from the others (P<0.05). Thereby, pulse contour analysis tended to underestimate SVV during decreased afterload and to overestimate SVV during increased afterload. Limits of agreement were approximately 6% for all points of measurement.
Conclusions: Left ventricular SVV is not affected by changes in cardiac afterload. There is a good agreement of pulse contour with flow derived SVV. The agreement decreases, if afterload is extensively augmented.
Comment in
-
Validation of pulse contour derived stroke volume variation.Br J Anaesth. 2007 Nov;99(5):745-6; author reply 746. doi: 10.1093/bja/aem284. Br J Anaesth. 2007. PMID: 17933802 No abstract available.
Similar articles
-
Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients.Intensive Care Med. 2003 Mar;29(3):476-80. doi: 10.1007/s00134-003-1649-7. Epub 2003 Feb 11. Intensive Care Med. 2003. PMID: 12579420 Clinical Trial.
-
Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.J Clin Monit Comput. 2016 Oct;30(5):587-94. doi: 10.1007/s10877-015-9759-7. Epub 2015 Aug 29. J Clin Monit Comput. 2016. PMID: 26318314 Free PMC article.
-
Functional hemodynamic parameters do not reflect volume responsiveness in the immediate phase after acute myocardial ischemia and reperfusion.J Cardiothorac Vasc Anesth. 2011 Oct;25(5):780-3. doi: 10.1053/j.jvca.2010.09.001. Epub 2010 Nov 5. J Cardiothorac Vasc Anesth. 2011. PMID: 21115364
-
Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children.Pediatr Crit Care Med. 2011 Jul;12(4):459-66. doi: 10.1097/PCC.0b013e3182070959. Pediatr Crit Care Med. 2011. PMID: 21263372 Review.
-
Functional haemodynamic monitoring.Curr Opin Crit Care. 2014 Jun;20(3):288-93. doi: 10.1097/MCC.0000000000000090. Curr Opin Crit Care. 2014. PMID: 24722057 Free PMC article. Review.
Cited by
-
Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum.J Clin Monit Comput. 2018 Oct;32(5):825-832. doi: 10.1007/s10877-017-0081-4. Epub 2017 Nov 17. J Clin Monit Comput. 2018. PMID: 29149433
-
Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect.Pediatr Cardiol. 2010 Nov;31(8):1166-70. doi: 10.1007/s00246-010-9776-8. Epub 2010 Aug 13. Pediatr Cardiol. 2010. PMID: 20703453
-
[Hemodynamic monitoring in one-lung ventilation].Anaesthesist. 2009 Nov;58(11):1085-96. doi: 10.1007/s00101-009-1632-y. Anaesthesist. 2009. PMID: 19915882 Review. German.
-
Preoperative carbohydrate loading and intraoperative goal-directed fluid therapy for elderly patients undergoing open gastrointestinal surgery: a prospective randomized controlled trial.BMC Anesthesiol. 2021 May 21;21(1):157. doi: 10.1186/s12871-021-01377-8. BMC Anesthesiol. 2021. PMID: 34020596 Free PMC article. Clinical Trial.
-
Assessment of central hemodynamic effects of phenylephrine: an animal experiment.J Clin Monit Comput. 2019 Jun;33(3):377-384. doi: 10.1007/s10877-018-0204-6. Epub 2018 Sep 27. J Clin Monit Comput. 2019. PMID: 30264219