Clinical significance of microembolus detection by transcranial Doppler sonography in cardiovascular clinical conditions
- PMID: 17462357
- DOI: 10.1016/j.ijsu.2005.12.001
Clinical significance of microembolus detection by transcranial Doppler sonography in cardiovascular clinical conditions
Abstract
Transcranial Doppler can detect microembolic signals, which are characterized by unidirectional high intensity increase, short duration, and random occurrence, producing a "whistling" sound. Microembolic signals have been proven to represent solid or gaseous particles within the blood flow. Microemboli have been detected in a number of clinical cardiovascular settings: carotid artery stenosis, aortic arch plaques, atrial fibrillation, myocardial infarction, prosthetic heart valves, patent foramen ovale, valvular stenosis, during invasive procedures (angiography, percutaneous transluminal angioplasty) and surgery (carotid, cardiopulmonary bypass). Despite numerous studies performed so far, clinical significance of microembolic signals is still unclear. This article provides an overview of the development and current state of technical and clinical aspects of microembolus detection.
Similar articles
-
Microembolus detection by transcranial Doppler sonography: review of the literature.Stroke Res Treat. 2012;2012:382361. doi: 10.1155/2012/382361. Epub 2011 Nov 30. Stroke Res Treat. 2012. PMID: 22195291 Free PMC article.
-
Microembolus detection by transcranial doppler sonography.Eur J Ultrasound. 2002 Nov;16(1-2):21-30. doi: 10.1016/s0929-8266(02)00046-0. Eur J Ultrasound. 2002. PMID: 12470847 Review.
-
Clinical application of transcranial Doppler monitoring for embolic signals.J Clin Neurosci. 2006 Oct;13(8):799-810. doi: 10.1016/j.jocn.2005.12.026. Epub 2006 Sep 5. J Clin Neurosci. 2006. PMID: 16908159 Review.
-
Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty.Stroke. 1998 Nov;29(11):2367-70. doi: 10.1161/01.str.29.11.2367. Stroke. 1998. PMID: 9804650
-
Transcranial Doppler ultrasonography in intensive care.Eur J Anaesthesiol Suppl. 2008;42:167-73. doi: 10.1017/S0265021507003341. Eur J Anaesthesiol Suppl. 2008. PMID: 18289437 Review.
Cited by
-
Cerebral microemboli in mini-sternotomy compared to mini- thoracotomy for aortic valve replacement: a cross sectional cohort study.J Cardiothorac Surg. 2021 May 24;16(1):142. doi: 10.1186/s13019-021-01509-8. J Cardiothorac Surg. 2021. PMID: 34030698 Free PMC article.
-
Transcranial Doppler microemboli and acute brain injury in extracorporeal membrane oxygenation: A prospective observational study.JTCVS Tech. 2022 Aug 20;15:111-122. doi: 10.1016/j.xjtc.2022.07.026. eCollection 2022 Oct. JTCVS Tech. 2022. PMID: 36276670 Free PMC article.
-
High-Intensity Transient Signals Detected in a Renal Allograft.Case Rep Transplant. 2023 Nov 8;2023:9921063. doi: 10.1155/2023/9921063. eCollection 2023. Case Rep Transplant. 2023. PMID: 38024225 Free PMC article.
-
The role of atrial fibrillation in vascular cognitive impairment and dementia: epidemiology, pathophysiology, and preventive strategies.Geroscience. 2025 Feb;47(1):287-300. doi: 10.1007/s11357-024-01290-1. Epub 2024 Aug 13. Geroscience. 2025. PMID: 39138793 Free PMC article. Review.
LinkOut - more resources
Full Text Sources