Mechanized astigmatic arcuate keratotomy with the Hanna arcitome for astigmatism after keratoplasty

Affiliations

Mechanized astigmatic arcuate keratotomy with the Hanna arcitome for astigmatism after keratoplasty

Louis Hoffart et al. J Cataract Refract Surg. 2007 May.

Abstract

Purpose: To report the results of correction of post-keratoplasty astigmatism by arcuate keratotomy performed with the Hanna arcitome (Moria).

Setting: Service 5, Hôpital des 15-20, Paris VI University, Paris, France.

Methods: Forty eyes operated on for post-keratoplasty astigmatism using the Hanna arcitome were retrospectively studied. Paired symmetrical arcuate keratotomies were performed on the graft button. Mean follow-up was 10.8 months +/- 11.2 (SD). Outcome measures included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and subjective refraction. For statistical analysis, visual acuity data were transformed into logMAR units. The refractive data were analyzed using the Alpins method.

Results: By a mean of 10.8 +/- 11.2 months after surgery, the UCVA had improved a mean of 0.28 +/- 0.46 lines, which was significant (P = .013). The BSCVA remained stable. The mean subjective cylinder was 8.84 +/- 3.00 diopters (D) preoperatively and 4.88 +/- 2.50 D postoperatively (P<.001). The changes in postoperative subjective cylinder values correlated with preoperative cylinder values (r(s) = 0.584; P<.0001). The subjective axis was modified by 20 degrees or less in 27 eyes (67.5%). The mean surgically induced astigmatism was 8.07 +/- 3.83 D and the mean correction index, 0.96 +/- 0.46. One microperforation occurred and required suturing. Incisions were off center in 1 case, and 2 patients had an allograft rejection after the procedure.

Conclusions: Arcuate keratotomy performed with the Hanna arcitome was effective in reducing post-keratoplasty astigmatism. The device enabled safer, easier arcuate incisions than with manual techniques. However, predictability and efficacy could be improved by a more accurate nomogram.