Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2008;21(1):47-53.
doi: 10.1016/j.pupt.2006.11.003. Epub 2006 Dec 14.

Efficacy and safety of formoterol delivered through the Novolizer, a novel dry powder inhaler (DPI) compared with a standard DPI in patients with moderate to severe asthma

Affiliations
Randomized Controlled Trial

Efficacy and safety of formoterol delivered through the Novolizer, a novel dry powder inhaler (DPI) compared with a standard DPI in patients with moderate to severe asthma

R Otto-Knapp et al. Pulm Pharmacol Ther. 2008.

Abstract

Background & objective: Because of environmental concerns CFC-containing pressurised metered dose inhalers (pMDI) had to be replaced by dry powder inhalers (DPI). The Novolizer, a novel DPI has previously been shown to be as effective as the Turbuhaler in delivering budesonide. The objective of this study was to show non-inferiority of inhaled formoterol therapy delivered through the Novolizer compared to formoterol delivered through the Aerolizer in patients suffering from moderate to severe asthma.

Methods: In this double-blind, double-dummy, multicentre study 392 patients were randomised and received a dose of 12 microg formoterol twice daily for 4 weeks either through the Aerolizer or the Novolizer. FEV1 after 4 weeks of treatment was the primary variable. Secondary variables were FVC, PEF, consumption of short-acting; 2 adrenoceptor agonists, asthma symptoms, tolerability and safety.

Results: After 4 weeks of treatment, the mean trough FEV1 (95% CI) was 2.34 L (2.24-2.45) for the Novolizer and 2.31 L (2.21-2.41) for the Aerolizer. Non-inferiority was proven (p<0.0001, pre-defined; of 0.25 L). All secondary variables (incl. PEF) confirmed these findings. Treatment with both devices was safe and well tolerated.

Conclusion: Inhalation of 12 microg formoterol twice daily via Novolizer was shown to be equally therapeutically effective compared to the inhalation via Aerolizer in the treatment of moderate to severe persistent asthma. Treatment via both inhalers was safe and well tolerated.

PubMed Disclaimer

Publication types