Randomized Controlled Trial
. 2007 Jul;56(7):656-64.
doi: 10.1007/s00101-007-1189-6.

[Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations]

[Article in German]
Affiliations
Randomized Controlled Trial

[Non-invasive extended hemodynamic monitoring. Reduction of circulatory risk situations]

[Article in German]
M Bock et al. Anaesthesist. 2007 Jul.

Abstract

Background: Cardiac output and the cardiac index (CI) are not routinely monitored during major abdominal surgery for economic as well as medical reasons. This practice, however, might be changed by the application of newer non-invasive technologies like the partial CO(2) rebreathing method based on the inverse Fick's principle. In this prospective randomized study we investigated the impact of a non-invasive monitoring of CI on the incidence of hemodynamic instability and interventions by the attending anesthesiologist during major abdominal surgery.

Patients and methods: Additionally to routine hemodynamic monitoring we measured CI using the partial CO(2) rebreathing method in 28 patients (9 female, 19 male) undergoing major abdominal surgery. In group I the anesthesiologists were aware of the results of the extended hemodynamic monitoring and in group II the attending anesthesiologist was blinded to the information obtained by these measurements of CI.

Results: Groups did not differ with regard to the baseline hemodynamic parameters. We obtained 923 measurements in both groups and 95 situations of hemodynamic instability (CI<2.5 l/minxm(2)) were detected in group I compared to 147 situations in group II (p<0.05). There were significantly more hemodynamic interventions in group I than in group II (p<0.0001). The cardiac index remained higher in group I in comparison to group II (p<0.0001). Measurement of CI was the only method to detect situations of hemodynamic instability in our setting.

Conclusion: The incidence of hemodynamic instability was significantly reduced during major abdominal surgery when anesthesiologists were aware of the measurement results of extended hemodynamic monitoring.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Emerg Med. 1995 Nov;13(6):626-31 - PubMed
    1. Clin Sci (Lond). 2004 Jan;106(1):3-10 - PubMed
    1. J Cardiothorac Vasc Anesth. 2001 Oct;15(5):567-73 - PubMed
    1. IEEE Trans Biomed Eng. 1988 Sep;35(9):653-61 - PubMed
    1. Acta Anaesthesiol Scand. 2002 Feb;46(2):152-9 - PubMed

Publication types

LinkOut - more resources