Comparative Study
. 2007 Dec;93(12):1562-6.
doi: 10.1136/hrt.2006.107052. Epub 2007 May 4.

Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size

Affiliations
Comparative Study

Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size

Shahid Aziz et al. Heart. 2007 Dec.

Abstract

Background: There is a strong inverse relationship between final vessel diameter and subsequent risk of treatment failure after coronary stent deployment. The aim of this study was to investigate the magnitude by which stent delivery balloon underexpansion and stent elastic recoil contributed to suboptimal final vessel geometry.

Methods: A prospective angiographic study recruiting 499 lesions (385 patients) undergoing coronary stent implantation was performed. Quantitative coronary angiography (QCA) was used to measure the minimal lumen diameters of the delivery balloon during stent deployment (MLD1) and of the stented segment following balloon deflation (MLD2). The expected balloon diameter for the deployment pressure was determined from the manufacturer's reference chart. Delivery balloon deficit was measured by subtracting the MLD1 from the expected balloon size and stent recoil was calculated by subtracting MLD2 from MLD1. Delivery balloon deficit and stent recoil were examined as a function of reference vessel diameter (RVD) and balloon-vessel (BV) ratio.

Results: The final stent MLD was a mean 27.2% (SD = 7.2) less than the predicted diameter. The mean delivery balloon deficit was 0.65 mm (SD = 0.27) and the mean stent recoil was 0.28 mm (SD = 0.17). Percentage delivery balloon deficit and stent recoil were independent of RVD. Delivery balloon deficit increased with higher BV ratios. Stent recoil was independent of BV ratio and the use of predilatation.

Conclusion: Failure to achieve predicted final stent diameter is a real problem with contribution from delivery balloon underexpansion and stent recoil. On average the final stent MLD is only 73% of the expected diameter, irrespective of vessel size.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None.

Comment in

  • Coronary stenting: why size matters.
    De Benedetti E, Urban P. De Benedetti E, et al. Heart. 2007 Dec;93(12):1500-1. doi: 10.1136/hrt.2006.113860. Heart. 2007. PMID: 18003677 Free PMC article.

References

    1. Bermejo J, Botas J, Garcia E.et al Mechanisms of residual lumen stenosis after high‐pressure stent implantation: a quantitative coronary angiography and intravascular ultrasound study. Circulation 199898112–118. - PubMed
    1. Bakhai A, Booth J, Delahunty N.et al The SV stent study: a prospective, multicentre, angiographic evaluation of the BiodivYsio phosphorylcholine coated small vessel stent in small coronary vessels. Int J Cardiol 200510295–102. - PubMed
    1. Gronenschild E, Janssen J, Tijdens F. CAAS. II: A second generation system for off‐line and on‐line quantitative coronary angiography. Cathet Cardiovasc Diagn 19943361–75. - PubMed
    1. Takano Y, Yeatman L A, Higgins J R.et al Optimizing stent expansion with new stent delivery systems. J Am Coll Cardiol 2001381622–1627. - PubMed
    1. Hehrlein C, DeVries J J, Wood T A.et al Overestimation of stent delivery balloon diameters by manufacturers' compliance tables: a quantitative coronary analysis of Duet and NIR stent implantation. Catheter Cardiovasc Interv 200153474–478. - PubMed

Publication types