Abstract
Assessment of cytokines in body fluids, cells or tissues provides important information in understanding of disease process and designing treatment strategies. Today, wide range of cytokine assays are available, including; measurement of levels of cytokines (direct) or cytokine soluble receptor levels (indirect) in body fluids or cellular supernatants (immunoassays and cytokine bioassays), measurement of cytokines produced by population of cells (multiparametric flow cytometry, magnetic beads based quantitation of cytokine producing cells, mRNA based assays), measurement of cytokines produced by single cells (Enzyme-linked immunospot (ELISPOT), Intra-cytoplasmic cytokine staining (ICC), mRNA based assays) and detection of cytokines in tissues (immunostaining). Improved understanding of cytokine interactions has led to a consensus that simultaneous assessment of many cytokines in a biological sample provides more comprehensive information rather than assessing a single cytokine. Thus, technologies that measure one cytokine at a time are being gradually replaced by multiplex-type formats (DNA and protein microarrays).
Similar articles
-
Performance evaluation of cytometric bead assays for the measurement of lung cytokines in two rodent models.J Immunol Methods. 2008 Feb 29;331(1-2):59-68. doi: 10.1016/j.jim.2007.11.004. Epub 2007 Dec 17. J Immunol Methods. 2008. PMID: 18089291
-
Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay.J Immunol Methods. 1999 Jul 30;227(1-2):41-52. doi: 10.1016/s0022-1759(99)00069-1. J Immunol Methods. 1999. PMID: 10485253
-
The clinical usefulness of the measurement of cytokines.Clin Chem Lab Med. 2000 Apr;38(4):267-85. doi: 10.1515/CCLM.2000.040. Clin Chem Lab Med. 2000. PMID: 10928646 Review.
-
Detecting Secreted Analytes from Immune Cells: An Overview of Technologies.Methods Mol Biol. 2016;1458:111-24. doi: 10.1007/978-1-4939-3801-8_9. Methods Mol Biol. 2016. PMID: 27581018
-
Multiplex cytokine analysis technologies.Expert Rev Vaccines. 2010 Oct;9(10):1231-7. doi: 10.1586/erv.10.110. Expert Rev Vaccines. 2010. PMID: 20923272 Review.
Cited by
-
A Simple Microfluidic Platform for Long-Term Analysis and Continuous Dual-Imaging Detection of T-Cell Secreted IFN-γ and IL-2 on Antibody-Based Biochip.Biosensors (Basel). 2015 Dec 4;5(4):750-67. doi: 10.3390/bios5040750. Biosensors (Basel). 2015. PMID: 26690235 Free PMC article.
-
Simultaneous Detection of Antigen-Specific IgG- and IgM-Secreting Cells with a B Cell Fluorospot Assay.Cells. 2012 Mar 21;1(1):15-26. doi: 10.3390/cells1010015. Cells. 2012. PMID: 24710360 Free PMC article.
-
An Attomolar-Level Optical Device for Monitoring Receptor-Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection.Sensors (Basel). 2025 Feb 4;25(3):930. doi: 10.3390/s25030930. Sensors (Basel). 2025. PMID: 39943569 Free PMC article.
-
Cytokine profiling of pancreatic fluid using the ePFT collection method in tandem with a multiplexed microarray assay.J Immunol Methods. 2011 Jun 30;369(1-2):98-107. doi: 10.1016/j.jim.2011.04.012. Epub 2011 May 1. J Immunol Methods. 2011. PMID: 21569776 Free PMC article.
-
Differentiating Branch Duct and Mixed IPMN in Endoscopically Collected Pancreatic Cyst Fluid via Cytokine Analysis.Gastroenterol Res Pract. 2012;2012:247309. doi: 10.1155/2012/247309. Epub 2012 Dec 25. Gastroenterol Res Pract. 2012. PMID: 23326260 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources