Clinical Trial
. 2007 Sep;33(9):1557-62.
doi: 10.1007/s00134-007-0665-4. Epub 2007 May 8.

Renal arterial resistance in septic shock: effects of increasing mean arterial pressure with norepinephrine on the renal resistive index assessed with Doppler ultrasonography

Affiliations
Clinical Trial

Renal arterial resistance in septic shock: effects of increasing mean arterial pressure with norepinephrine on the renal resistive index assessed with Doppler ultrasonography

Stéphane Deruddre et al. Intensive Care Med. 2007 Sep.

Abstract

Objective: To determine the effects of increasing mean arterial pressure (MAP) on renal resistances assessed by Doppler ultrasonography in septic shock.

Design and setting: Prospective, single-center, nonrandomized, open-label trial in the surgical intensive care unit in a university teaching hospital.

Patients and participants: 11 patients with septic shock who required fluid resuscitation and norepinephrine to increase and maintain MAP at or above 65 mmHg.

Interventions: Norepinephrine was titrated in 11 patients in septic shock during three consecutive not randomized periods of 2 h to achieve a MAP at successively 65, 75, and 85 mmHg.

Measurements and results: At the end of each period hemodynamic parameters and renal function variables (urinary output, creatinine, clearance) were measured, and Doppler ultrasonography was performed on interlobar arteries to assess the renal resistive index. When increasing MAP from 65 to 75 mmHg, urinary output increased significantly from 76 +/- 64 to 93 +/- 68 ml/h and the resistive index significantly decreased from 0.75 +/- 0.07 to 0.71 +/- 0.06. No difference was found between 75 and 85 mmHg.

Conclusions: Doppler ultrasonography and resistive index measurements may help determine in each patient the optimal MAP for renal blood flow and may be a relevant end-point to titrate the hemodynamic treatment in septic shock.

PubMed Disclaimer

References

    1. J Trauma. 2002 Aug;53(2):267-71 - PubMed
    1. N Engl J Med. 2003 Jul 10;349(2):115-24 - PubMed
    1. Hypertension. 2002 Feb;39(2 Pt 2):699-703 - PubMed
    1. J Ultrasound Med. 1995 Jun;14 (6):427-9 - PubMed
    1. Am J Hypertens. 2005 Jul;18(7):966-71 - PubMed

Publication types

MeSH terms