Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Nov;17(11):2838-44.
doi: 10.1007/s00330-007-0647-5. Epub 2007 May 8.

Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study

Affiliations
Comparative Study

Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study

Jean-Christophe Lasalarie et al. Eur Radiol. 2007 Nov.

Abstract

The accuracy of contrast-enhanced cine magnetic resonance (cine-MR) imaging to determine left ventricular function was assessed by comparison with the established noncontrast cine-MR sequences. Contrast-enhanced balanced steady-state free precession (cine-SSFP) sequences were compared with precontrast cine-SSFP sequences in the assessment of left ventricular contractile function in 30 consecutive patients with various cardiac diseases. Five to eight short-axis image sections were obtained in each patient. Quantitative data were analyzed using a paired t-test and linear regression analysis. Qualitative assessment of images was made following a 16-segment analysis. There was no significant difference between the two sequences in regional wall motion, end-diastolic volumes (EDV) and end-systolic volumes (ESV), stroke volume, left ventricular mass, as well as left ventricular ejection fraction (LVEF), despite slight delayed subendocardial enhancement in ten patients with myocardial infarction. All the values studied above were closely correlated between both cine-SSFP sequences (Spearman r=0.85-0.97, P<0.0001 for all comparisons). Contrast-enhanced cine-SSFP sequences can be used as a similar diagnostic tool as precontrast cine-MR sequences in the assessment of left ventricular contractile function.

PubMed Disclaimer

References

    1. Radiographics. 2003 Oct;23 Spec No:S127-40 - PubMed
    1. Radiology. 2001 Apr;219(1):264-9 - PubMed
    1. Eur Radiol. 2003 Nov;13(11):2409-18 - PubMed
    1. Eur Radiol. 2006 Jul;16(7):1424-33 - PubMed
    1. J Magn Reson Imaging. 2001 Oct;14(4):362-7 - PubMed

LinkOut - more resources