Value of ultrasound-guided core biopsy in the diagnosis of malignant lymphoma
- PMID: 17486566
- DOI: 10.1002/jcu.20383
Value of ultrasound-guided core biopsy in the diagnosis of malignant lymphoma
Abstract
Purpose: Ultrasound-guided core needle biopsy for the diagnosis and management of malignant lymphomas is controversial and has not been accepted as an alternative to surgical biopsy. We investigate the clinical usefulness of this procedure in a large series of patients.
Methods: Over a 5-year period (2000-2004), ultrasound-guided core needle biopsies were performed in 102 malignant lymphomas. Five diagnostic categories were considered: large B-cell lymphomas (LBCL), small B-cell lymphomas (SBCL), Hodgkin's disease (HD), T cell lymphomas, and miscellaneous. Surgical excisional biopsy of the node was performed in 47 cases (46.1%) for diagnostic confirmation.
Results: The overall diagnostic accuracy of ultrasound-guided core needle biopsy was 88.2% (90/102). SBCL (39), LBCL (36), HD (15), T cell lymphomas (5), and miscellaneous (7) [including T cell-rich B cell (2), natural killer cell (1), Burkitt's lymphoma (1), and non-Hodgkin's lymphoma of the B cell type, NOS (3)] were correctly diagnosed. Three HDs, 1 natural killer cell lymphoma, 1 follicular lymphoma, and 1 LBCL were not correctly diagnosed. The core needle biopsy did not yield tumor tissue in 6 cases.
Conclusions: Ultrasound-guided core needle biopsy is effective in the diagnosis of malignant lymphomas and can be used as the first diagnostic approach in selected clinical situations.
(c) 2007 Wiley Periodicals, Inc.
Similar articles
-
[Paraneoplastic lymphadenopathy].Ter Arkh. 2007;79(8):44-52. Ter Arkh. 2007. PMID: 17926471 Russian.
-
Diagnosis and subclassification of primary and recurrent lymphoma. The usefulness and limitations of combined fine-needle aspiration cytomorphology and flow cytometry.Am J Clin Pathol. 2000 May;113(5):688-99. doi: 10.1309/0Q7F-QTGM-6DPD-TLGY. Am J Clin Pathol. 2000. PMID: 10800402
-
The "large cell" malignant lymphomas. A retrospective morphological analysis.Med Interne. 1980 Jul-Sep;18(3):333-8. Med Interne. 1980. PMID: 6997976
-
Fine needle aspiration cytopathology of malignant lymphoma.Clin Lab Med. 1998 Sep;18(3):541-59, vi-vii. Clin Lab Med. 1998. PMID: 9742382 Review.
-
Serous effusions in malignant lymphomas: a review.Diagn Cytopathol. 2006 May;34(5):335-47. doi: 10.1002/dc.20432. Diagn Cytopathol. 2006. PMID: 16604559 Review.
Cited by
-
Is percutaneous computed tomography-guided biopsy sufficient to establish indolent lymphoma transformation?Arch Med Sci. 2019 Oct;15(6):1443-1453. doi: 10.5114/aoms.2018.79573. Epub 2018 Dec 31. Arch Med Sci. 2019. PMID: 31749872 Free PMC article.
-
Clinical application of ultrasound-guided core needle biopsy with multiple punches in the diagnosis of lymphoma.World J Surg Oncol. 2015 Mar 27;13:126. doi: 10.1186/s12957-015-0537-2. World J Surg Oncol. 2015. PMID: 25885784 Free PMC article.
-
Diagnostic Performance and Safety of Ultrasound-Guided Core Needle Biopsy for Diagnosing Lymphoma: A Systematic Review and Meta-Analysis.Cancer Med. 2025 Jan;14(1):e70414. doi: 10.1002/cam4.70414. Cancer Med. 2025. PMID: 39757781 Free PMC article.
-
US-guided percutaneous needle biopsy of anterior mediastinal masses in children.Pediatr Radiol. 2012 Jan;42(1):40-9. doi: 10.1007/s00247-011-2204-2. Epub 2011 Aug 24. Pediatr Radiol. 2012. PMID: 21863292
-
Ultrasound-guided core biopsy in the diagnosis of lymphoma of the head and neck. A 9 year experience.Br J Radiol. 2011 Aug;84(1004):727-32. doi: 10.1259/bjr/60580076. Epub 2011 Mar 22. Br J Radiol. 2011. PMID: 21427181 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical