Comparison of heating devices for maintaining body temperature in anesthetized laboratory rabbits (Oryctolagus cuniculus)
- PMID: 17487956
Comparison of heating devices for maintaining body temperature in anesthetized laboratory rabbits (Oryctolagus cuniculus)
Abstract
The purpose of this study was to compare the efficacy of various external heating devices in maintaining body temperature in anesthetized rabbits (Oryctolagus cuniculus). Rabbits were divided into 3 groups and placed on either no heating device, a circulating warm-water blanket, or a forced-air warming device. The animals underwent identical surgical procedures unrelated to the scope of the study, and body temperatures were monitored at 5-min intervals for a 45-min period. Results showed that rabbits had a statistically significant loss of body temperature during the procedure when no heating device was used, no significant loss in body temperature with the use of the forced air-warming device, and a minor increase in body temperature with the use of the circulating warm-water blanket. This study shows that external heating devices are necessary for maintenance of normal body temperature in rabbits under general anesthesia, and forced-air warming devices and circulating warm-water blankets are effective heating devices.
Similar articles
-
Study of two devices used to maintain normothermia in rats and mice during general anesthesia.J Am Assoc Lab Anim Sci. 2007 Sep;46(5):37-41. J Am Assoc Lab Anim Sci. 2007. PMID: 17877326
-
Skin-surface warming: heat flux and central temperature.Anesthesiology. 1990 Aug;73(2):218-24. Anesthesiology. 1990. PMID: 2382847
-
A comparison of a forced-air warming system to traditional thermal support for rodent microenvironments.Lab Anim. 2004 Jan;38(1):55-63. doi: 10.1258/00236770460734407. Lab Anim. 2004. PMID: 14979989
-
[Non-therapeutic intraoperative hypothermia: prevention and treatment (part II)].Rev Esp Anestesiol Reanim. 2003 Apr;50(4):197-208. Rev Esp Anestesiol Reanim. 2003. PMID: 12825309 Review. Spanish.
-
Forced-air warming: technology, physical background and practical aspects.Curr Opin Anaesthesiol. 2009 Dec;22(6):769-74. doi: 10.1097/ACO.0b013e328331d134. Curr Opin Anaesthesiol. 2009. PMID: 19734783 Review.
Cited by
-
Comparison of thermoregulatory devices used during anesthesia of C57BL/6 mice and correlations between body temperature and physiologic parameters.J Am Assoc Lab Anim Sci. 2013 Sep;52(5):577-83. J Am Assoc Lab Anim Sci. 2013. PMID: 24041214 Free PMC article.
-
Performance and Consistency of Circulating Warm Water Blankets for Rodents.J Am Assoc Lab Anim Sci. 2022 Jan 1;61(1):96-100. doi: 10.30802/AALAS-JAALAS-21-000073. Epub 2022 Jan 3. J Am Assoc Lab Anim Sci. 2022. PMID: 34980293 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical