Second-generation endometrial ablation treatment: Novasure
- PMID: 17490913
- DOI: 10.1016/j.bpobgyn.2007.03.024
Second-generation endometrial ablation treatment: Novasure
Abstract
The Novasure endometrial ablation system consists of a single-use device and a radiofrequency controller. It is a three-dimensional, triangular-shaped bipolar ablation device. The generator functions at 500 kHz and has a power cut-off limit set at a tissue impedance of 50 Ohms. The self-terminating procedure is based on tissue impedance or time. A cavity assessment system works to detect perforations in the uterine cavity. No pretreatment is necessary. Randomized controlled trials have shown that the Novasure system has an amenorrhoea rate of 44-56% at 1-year follow-up, and the 5-year results of a randomized trial will be published shortly. Prospective observational studies show even higher amenorrhoea rates of up to 58-75% up to 5-year follow-up. Hysterectomy rates in the prospective trial were very low (4%). In summary, the Novasure endometrial ablation system is an effective second-generation ablation technique, resulting in a high percentage of amenorrhoea.
Similar articles
-
Five-year follow up of a randomised controlled trial comparing NovaSure and ThermaChoice endometrial ablation.BJOG. 2008 Jan;115(2):193-8. doi: 10.1111/j.1471-0528.2007.01427.x. Epub 2007 Jul 6. BJOG. 2008. PMID: 17617188 Clinical Trial.
-
NovaSure impedance controlled system for endometrial ablation: three-year follow-up on 107 patients.Am J Obstet Gynecol. 2004 Nov;191(5):1585-9. doi: 10.1016/j.ajog.2004.05.020. Am J Obstet Gynecol. 2004. PMID: 15547528
-
Endometrial ablation with NovaSure GEA, a pilot study.Acta Obstet Gynecol Scand. 2003 Jan;82(1):65-8. Acta Obstet Gynecol Scand. 2003. PMID: 12580843
-
Health technology assessment of surgical therapies for benign gynaecological disease.Best Pract Res Clin Obstet Gynaecol. 2006 Dec;20(6):841-79. doi: 10.1016/j.bpobgyn.2006.11.006. Best Pract Res Clin Obstet Gynaecol. 2006. PMID: 17145485 Review.
-
Summary of safety and effectiveness data from FDA: a valuable source of information on the performance of global endometrial ablation devices.J Reprod Med. 2004 Apr;49(4):267-73. J Reprod Med. 2004. PMID: 15134151 Review.
Cited by
-
Antenna Designs for Microwave Tissue Ablation.Crit Rev Biomed Eng. 2018;46(6):495-521. doi: 10.1615/CritRevBiomedEng.2018028554. Crit Rev Biomed Eng. 2018. PMID: 30806212 Free PMC article. Review.
-
Does the radiofrequency impedance-controlled endometrial ablation have any morphologic effects on uterine leiomyomata? Report of 3 cases.Diagn Pathol. 2008 Jul 1;3:28. doi: 10.1186/1746-1596-3-28. Diagn Pathol. 2008. PMID: 18593468 Free PMC article.
-
Cost effectiveness of endometrial ablation with the NovaSure(®) system versus other global ablation modalities and hysterectomy for treatment of abnormal uterine bleeding: US commercial and Medicaid payer perspectives.Int J Womens Health. 2015 Jan 6;7:59-73. doi: 10.2147/IJWH.S75030. eCollection 2015. Int J Womens Health. 2015. PMID: 25610002 Free PMC article.
-
Retrospective study on the outcomes and satisfaction with endometrial ablation by bipolar energy (NovaSure®) for the treatment of heavy menstrual bleeding.Arch Gynecol Obstet. 2025 Feb;311(2):385-393. doi: 10.1007/s00404-024-07726-5. Epub 2024 Sep 13. Arch Gynecol Obstet. 2025. PMID: 39269466 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources