[The reconstruction of extended acetabular bone defects in revision hip arthroplasty--risk factors for migration and loosening using the pedestal cup]
- PMID: 17492557
- DOI: 10.1055/s-2007-965102
[The reconstruction of extended acetabular bone defects in revision hip arthroplasty--risk factors for migration and loosening using the pedestal cup]
Abstract
Aim: For the reconstruction of extended acetabular bone defects in revision hip arthroplasty different implants and techniques are available.However, in cases with a broad operative range of new implants, specific indications must be determined. The aim of this study is to determine the risk factors for migration and loosening associated with implantation of the pedestal cup.
Method: In a retrospective study the first 50 implantations of the pedestal cup in our hospital for high-grade acetabular defects (Paprosky classification II and III) were examined after a medium period of 26 months. Differences between radiologically loosened and osteal integrated implants in consideration of the preoperative osseous situation(defect size and morphology, bone density)as well as the implant positioning were determined as risk factors of an implant failure.
Results: Three (6%) intraoperative implant-associated complications occurred, which were in the phase of the initial learning curve. In the early postoperative period 10 hip dislocations (20%)occurred. Two septic loosenings (4%) and 6 aseptic loosenings (12%) were observed. In 7 further cases a significant migration of the implant was assessed in the first months after surgery, a solid osteal integration did not appear. As risk factors for an implant loosening were determined:a missing reconstruction of the defect behind the pedestal cup with allogenous bone graft(p = 0.002), a lateralisation of the rotation centre(p = 0.023), the absence of the craniolateral wall (p = 0.002) and the presence of osteoporosis(p = 0.026).
Conclusion: The pedestal cup is an implant that is well usable in many high-grade acetabular defect situations with good mid-term results; however,contraindications do exist. In cases with a significant osteoporosis, a missing sclerosis of the cranial acetabulum as well as extended damage of the lateral ilium and its absence, respectively, alternative procedures should be considered.
Similar articles
-
[Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft].Rev Chir Orthop Reparatrice Appar Mot. 2007 May;93(3):255-63. doi: 10.1016/s0035-1040(07)90247-0. Rev Chir Orthop Reparatrice Appar Mot. 2007. PMID: 17534208 French.
-
[Oblong acetabular cup, type TC, for revision total hip arthroplasty].Acta Chir Orthop Traumatol Cech. 2012;79(6):506-11. Acta Chir Orthop Traumatol Cech. 2012. PMID: 23286682 Czech.
-
Ganz reinforcement ring for reconstruction of acetabular defects in revision total hip arthroplasty.J Bone Joint Surg Am. 2003 Dec;85(12):2358-64. doi: 10.2106/00004623-200312000-00013. J Bone Joint Surg Am. 2003. PMID: 14668505
-
[Acetabular defect reconstruction in revision surgery of the hip. Autologous, homologous or metal?].Orthopade. 2009 Aug;38(8):729-40. doi: 10.1007/s00132-009-1428-4. Orthopade. 2009. PMID: 19672576 Review. German.
-
[Acetabular metastatic defect reconstruction using the modular revision support cup MRS-C].Oper Orthop Traumatol. 2024 Apr;36(2):145-156. doi: 10.1007/s00064-023-00834-6. Epub 2023 Nov 3. Oper Orthop Traumatol. 2024. PMID: 37921888 Free PMC article. Review. German.
Cited by
-
[Mega cups and partial pelvic replacement].Orthopade. 2010 Oct;39(10):931-41. doi: 10.1007/s00132-009-1568-6. Orthopade. 2010. PMID: 20862576 German.
-
Iliac Stemmed Cups: A Review of History, Indications, and Clinical Outcomes in Revision Hip Arthroplasty and Primary Severe Dysplasia.J Clin Med. 2025 Jul 13;14(14):4955. doi: 10.3390/jcm14144955. J Clin Med. 2025. PMID: 40725648 Free PMC article. Review.
-
[Comparison of different cup revision systems].Orthopade. 2009 Aug;38(8):704-10. doi: 10.1007/s00132-009-1429-3. Orthopade. 2009. PMID: 19693623 Review. German.
-
Acetabular Home Run Screw Guidance for Transiliac Fixation in Cup Revision Arthroplasty.J Clin Med. 2025 Jan 30;14(3):922. doi: 10.3390/jcm14030922. J Clin Med. 2025. PMID: 39941593 Free PMC article.
-
[Acetabular revision surgery with the oblong revision cup : clinical and radiological results of 217 cases].Orthopade. 2010 May;39(5):503-11. doi: 10.1007/s00132-009-1527-2. Orthopade. 2010. PMID: 19838666 German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials