Laparoscopic entry: a review of techniques, technologies, and complications
- PMID: 17493376
- DOI: 10.1016/S1701-2163(16)35496-2
Laparoscopic entry: a review of techniques, technologies, and complications
Abstract
Objective: To provide clinical direction, based on the best evidence available, on laparoscopic entry techniques and technologies and their associated complications.
Options: The laparoscopic entry techniques and technologies reviewed in formulating this guideline include the classic pneumoperitoneum (Veress/trocar), the open (Hasson), the direct trocar insertion, the use of disposable shielded trocars, radially expanding trocars, and visual entry systems.
Outcomes: Implementation of this guideline should optimize the decision-making process in choosing a particular technique to enter the abdomen during laparoscopy.
Evidence: English-language articles from Medline, PubMed, and the Cochrane Database published before the end of September 2005 were searched, using the key words laparoscopic entry, laparoscopy access, pneumoperitoneum, Veress needle, open (Hasson), direct trocar, visual entry, shielded trocars, radially expanded trocars, and laparoscopic complications.
Values: The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on the Periodic Health Examination. RECOMMENDATIONS AND SUMMARY STATEMENT: 1. Left upper quadrant (LUQ, Palmer's) laparoscopic entry should be considered in patients with suspected or known periumbilical adhesions or history or presence of umbilical hernia, or after three failed insufflation attempts at the umbilicus. (II-2 A) Other sites of insertion, such as transuterine Veress CO(2) insufflation, may be considered if the umbilical and LUQ insertions have failed or have been considered and are not an option. (I-A) 2. The various Veress needle safety tests or checks provide very little useful information on the placement of the Veress needle. It is therefore not necessary to perform various safety checks on inserting the Veress needle; however, waggling of the Veress needle from side to side must be avoided, as this can enlarge a 1.6 mm puncture injury to an injury of up to 1 cm in viscera or blood vessels. (II-1 A) 3. The Veress intraperitoneal (VIP-pressure </= 10 mm Hg) is a reliable indicator of correct intraperitoneal placement of the Veress needle; therefore, it is appropriate to attach the CO(2) source to the Veress needle on entry. (II-1 A) 4. Elevation of the anterior abdominal wall at the time of Veress or primary trocar insertion is not routinely recommended, as it does not avoid visceral or vessel injury. (II-2 B) 5. The angle of the Veress needle insertion should vary according to the BMI of the patient, from 45 degrees in non-obese women to 90 degrees in obese women. (II-2 B) 6. The volume of CO(2) inserted with the Veress needle should depend on the intra-abdominal pressure. Adequate pneumoperitoneum should be determined by a pressure of 20 to 30 mm Hg and not by predetermined CO(2) volume. (II-1 A) 7. In the Veress needle method of entry, the abdominal pressure may be increased immediately prior to insertion of the first trocar. The high intraperitoneal (HIP-pressure) laparoscopic entry technique does not adversely affect cardiopulmonary function in healthy women. (II-1 A) 8. The open entry technique may be utilized as an alternative to the Veress needle technique, although the majority of gynaecologists prefer the Veress entry. There is no evidence that the open entry technique is superior to or inferior to the other entry techniques currently available. (II-2 C) 9. Direct insertion of the trocar without prior pneumoperitoneum may be considered as a safe alternative to Veress needle technique. (II-2) 10. Direct insertion of the trocar is associated with less insufflation-related complications such as gas embolism, and it is a faster technique than the Veress needle technique. (I) 11. Shielded trocars may be used in an effort to decrease entry injuries. There is no evidence that they result in fewer visceral and vascular injuries during laparoscopic access. (II-B) 12. Radially expanding trocars are not recommended as being superior to the traditional trocars. They do have blunt tips that may provide some protection from injuries, but the force required for entry is significantly greater than with disposable trocars. (I-A) 13. The visual entry cannula system may represent an advantage over traditional trocars, as it allows a clear optical entry, but this advantage has not been fully explored. The visual entry cannula trocars have the advantage of minimizing the size of the entry wound and reducing the force necessary for insertion. Visual entry trocars are non-superior to other trocars since they do not avoid visceral and vascular injury. (2 B).
Similar articles
-
[Risks associated with laparoscopic entry].J Gynecol Obstet Biol Reprod (Paris). 2010 Dec;39(8 Suppl 2):S123-35. doi: 10.1016/S0368-2315(10)70039-9. J Gynecol Obstet Biol Reprod (Paris). 2010. PMID: 21185465 French.
-
No. 193-Laparoscopic Entry: A Review of Techniques, Technologies, and Complications.J Obstet Gynaecol Can. 2017 Jul;39(7):e69-e84. doi: 10.1016/j.jogc.2017.04.013. J Obstet Gynaecol Can. 2017. PMID: 28625296 Review.
-
Guideline No. 412: Laparoscopic Entry for Gynaecological Surgery.J Obstet Gynaecol Can. 2021 Mar;43(3):376-389.e1. doi: 10.1016/j.jogc.2020.12.012. Epub 2020 Dec 26. J Obstet Gynaecol Can. 2021. PMID: 33373697
-
Laparoscopic entry techniques.Cochrane Database Syst Rev. 2019 Jan 18;1(1):CD006583. doi: 10.1002/14651858.CD006583.pub5. Cochrane Database Syst Rev. 2019. PMID: 30657163 Free PMC article.
-
Risks associated with laparoscopic entry: guidelines for clinical practice from the French College of Gynaecologists and Obstetricians.Eur J Obstet Gynecol Reprod Biol. 2011 Oct;158(2):159-66. doi: 10.1016/j.ejogrb.2011.04.047. Epub 2011 May 31. Eur J Obstet Gynecol Reprod Biol. 2011. PMID: 21621318
Cited by
-
A multidisciplinary evidence-based guideline for minimally invasive surgery.: Part 1: entry techniques and the pneumoperitoneum.Gynecol Surg. 2012 Sep;9(3):271-282. doi: 10.1007/s10397-012-0731-y. Epub 2012 Feb 22. Gynecol Surg. 2012. PMID: 22837735 Free PMC article.
-
Bladder injuries in emergency/expedited laparoscopic surgery in the absence of previous surgery: a case series.Ann R Coll Surg Engl. 2012 Apr;94(3):e118-20. doi: 10.1308/003588412X13171221502149. Ann R Coll Surg Engl. 2012. PMID: 22507707 Free PMC article.
-
Laparoscopic-assisted cryptorchidectomy in 2 Vietnamese pot-bellied pigs (Sus scrofa).Can Vet J. 2015 Feb;56(2):153-6. Can Vet J. 2015. PMID: 25694664 Free PMC article.
-
Preprocedure patient preferences and attitudes toward permanent contraceptive options.Patient Prefer Adherence. 2012;6:331-6. doi: 10.2147/PPA.S30247. Epub 2012 Apr 17. Patient Prefer Adherence. 2012. PMID: 22563241 Free PMC article.
-
Left upper quadrant laparoscopic placement: effects of insertion angle and body mass index on distance to posterior peritoneum by magnetic resonance imaging.Am J Obstet Gynecol. 2009 Nov;201(5):522.e1-5. doi: 10.1016/j.ajog.2009.07.017. Epub 2009 Sep 17. Am J Obstet Gynecol. 2009. PMID: 19761999 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources