Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT
- PMID: 17495293
- DOI: 10.1148/rg.273065087
Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT
Abstract
At magnetic resonance (MR) imaging and multidetector computed tomography (CT), artifacts arising from metallic orthopedic hardware are an obstacle to obtaining optimal images. Although various techniques for reducing such artifacts have been developed and corroborated by previous researchers, a new era of more powerful MR imaging and multidetector CT modalities has renewed the importance of a systematic consideration of methods for artifact reduction. Knowledge of the factors that contribute to artifacts, of related theories, and of artifact reduction techniques has become mandatory for radiologists. Factors that affect artifacts on MR images include the composition of the metallic hardware, the orientation of the hardware in relation to the direction of the main magnetic field, the strength of the magnetic field, the pulse sequence type, and other MR imaging parameters (mainly voxel size, which is determined by the field of view, image matrix, section thickness, and echo train length). At multidetector CT, the factors that affect artifacts include the composition of the hardware, orientation of the hardware, acquisition parameters (peak voltage, tube charge, collimation, and acquired section thickness), and reconstruction parameters (reconstructed section thickness, reconstruction algorithm used, and whether an extended CT scale was used). A comparison of images obtained with different hardware and different acquisition and reconstruction parameters facilitates an understanding of methods for reducing or overcoming artifacts related to metallic implants.
(c) RSNA, 2007.
Similar articles
-
Managing postoperative artifacts on computed tomography and magnetic resonance imaging.Semin Musculoskelet Radiol. 2011 Sep;15(4):309-19. doi: 10.1055/s-0031-1286013. Epub 2011 Sep 16. Semin Musculoskelet Radiol. 2011. PMID: 21928156 Review.
-
SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging.Invest Radiol. 2012 May;47(5):267-76. doi: 10.1097/RLI.0b013e318240a919. Invest Radiol. 2012. PMID: 22266987
-
Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies.AJR Am J Roentgenol. 1998 Nov;171(5):1207-13. doi: 10.2214/ajr.171.5.9798849. AJR Am J Roentgenol. 1998. PMID: 9798849
-
Metal artifact reduction: standard and advanced magnetic resonance and computed tomography techniques.Radiol Clin North Am. 2015 May;53(3):531-47. doi: 10.1016/j.rcl.2014.12.005. Epub 2015 Feb 7. Radiol Clin North Am. 2015. PMID: 25953288 Review.
-
Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT.Radiographics. 2013 Mar-Apr;33(2):573-83. doi: 10.1148/rg.332125124. Radiographics. 2013. PMID: 23479714 Review.
Cited by
-
MRI with intraoral orthodontic appliance-a comparative in vitro and in vivo study of image artefacts at 1.5 T.Dentomaxillofac Radiol. 2015;44(6):20140416. doi: 10.1259/dmfr.20140416. Epub 2015 Mar 3. Dentomaxillofac Radiol. 2015. PMID: 25734243 Free PMC article.
-
Comparison of dual-energy computed tomography (DECT) polychromatic and monochromatic images with and without iterative metal artifact reduction algorithm in patients with dental implants.Quant Imaging Med Surg. 2024 Jul 1;14(7):4688-4702. doi: 10.21037/qims-24-19. Epub 2024 Jun 27. Quant Imaging Med Surg. 2024. PMID: 39022239 Free PMC article.
-
Novel biodegradable magnesium alloy clips compared with titanium clips for hepatectomy in a rat model.BMC Surg. 2019 Sep 9;19(1):130. doi: 10.1186/s12893-019-0600-y. BMC Surg. 2019. PMID: 31500601 Free PMC article.
-
Numerical approach to investigate MR imaging artifacts from orthopedic implants at different field strengths according to ASTM F2119.MAGMA. 2023 Oct;36(5):725-735. doi: 10.1007/s10334-023-01074-2. Epub 2023 Mar 18. MAGMA. 2023. PMID: 36933090 Free PMC article.
-
Risk assessment of copper-containing contraceptives: the impact for women with implanted intrauterine devices during clinical MRI and CT examinations.Eur Radiol. 2019 Jun;29(6):2812-2820. doi: 10.1007/s00330-018-5864-6. Epub 2018 Nov 19. Eur Radiol. 2019. PMID: 30456586