Evaluation of working length determination methods: an in vivo / ex vivo study
- PMID: 17502709
- DOI: 10.4103/0970-9290.32421
Evaluation of working length determination methods: an in vivo / ex vivo study
Abstract
This comparative study was done to determine the accuracy in measuring the working length of root canal using tactile method, electronic apex locator and radiographic method, in vivo and comparing the lengths so measured to the actual working length, ex vivo, after extraction. Thirty single-rooted teeth scheduled for extraction were selected for the study. After obtaining the consent from patients, a preoperative radiograph was taken and access opening was done. Working length was determined by tactile method, by using Ingle's radiographic method and by using a Foramatron-IV digital apex locator. The teeth were then extracted and the actual working length was determined by placing an endodontic file in the root canal 0.5 mm short of the apex. The results indicated that among the three methods, the electronic apex locator showed the highest accuracy and the highest reliability for working length determination.
Similar articles
-
Accuracy of a new apex locator: an in vitro study.Int Endod J. 2002 Feb;35(2):186-92. doi: 10.1046/j.1365-2591.2002.00468.x. Int Endod J. 2002. PMID: 11843975
-
Comparison of working length determination using apex locator, conventional radiography and radiovisiography: an in vitro study.J Contemp Dent Pract. 2012 Jul 1;13(4):550-3. doi: 10.5005/jp-journals-10024-1184. J Contemp Dent Pract. 2012. PMID: 23151708
-
[Determination of canal length in endodontics].Rev Belge Med Dent (1984). 2005;60(1):31-40. Rev Belge Med Dent (1984). 2005. PMID: 15943057 Review. French.
-
An in vivo comparative evaluation to determine the accuracy of working length between radiographic and electronic apex locators.Indian J Dent Res. 2012 May-Jun;23(3):359-62. doi: 10.4103/0970-9290.102226. Indian J Dent Res. 2012. PMID: 23059573
-
[Accuracy of 2 electronic canal length measuring instruments].Rev Fr Endod. 1991 Mar;10(1):27-33. Rev Fr Endod. 1991. PMID: 2020777 Review. French.
Cited by
-
Evaluation of the Working Length Determination Accuracy by Cone-beam Computed Tomography in Primary Teeth.Int J Clin Pediatr Dent. 2022;15(Suppl 1):S92-S96. doi: 10.5005/jp-journals-10005-2330. Int J Clin Pediatr Dent. 2022. PMID: 35645504 Free PMC article.
-
Comparison of electronic apex locator and simultaneous working length detection methods with radiological method in terms of postoperative pain.BMC Oral Health. 2024 Nov 19;24(1):1408. doi: 10.1186/s12903-024-05200-x. BMC Oral Health. 2024. PMID: 39563342 Free PMC article. Clinical Trial.
-
Comparison of two electronic apex locators on human cadavers.Clin Oral Investig. 2016 Sep;20(7):1547-50. doi: 10.1007/s00784-015-1644-8. Epub 2015 Nov 4. Clin Oral Investig. 2016. PMID: 26531192
-
Comparison of Accuracy of Apex Locator with Tactile and Conventional Radiographic Method for Working Length Determination in Primary and Permanent Teeth.Int J Clin Pediatr Dent. 2020 May-Jun;13(3):235-239. doi: 10.5005/jp-journals-10005-1768. Int J Clin Pediatr Dent. 2020. PMID: 32904087 Free PMC article.
-
Comparative Evaluation of the Accuracy of Electronic Apex Locator and Digital Radiography for Working Length Determination in Primary Teeth: A Systematic Review.J Dent (Shiraz). 2024 Sep 1;25(3):203-214. doi: 10.30476/dentjods.2023.97323.2006. eCollection 2024 Sep. J Dent (Shiraz). 2024. PMID: 39371951 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous