A simple device using magnetic transportation for droplet-based PCR
- PMID: 17505884
- DOI: 10.1007/s10544-007-9078-y
A simple device using magnetic transportation for droplet-based PCR
Abstract
The Polymerase chain reaction (PCR) was successfully and rapidly performed in a simple reaction device devoid of channels, pumps, valves, or other control elements used in conventional lab-on-a-chip technology. The basic concept of this device is the transportation of aqueous droplets containing hydrophilic magnetic beads in a flat-bottomed, tray-type reactor filled with silicone oil. The whole droplets sink to the bottom of the reactor because their specific gravity is greater than that of the silicone oil used here. The droplets follow the movement of a magnet located underneath the reactor. The notable advantage of the droplet-based PCR is the ability to switch rapidly the proposed reaction temperature by moving the droplets to the required temperature zones in the temperature gradient. The droplet-based reciprocative thermal cycling was performed by moving the droplets composed of PCR reaction mixture to the designated temperature zones on a linear temperature gradient from 50 degrees C to 94 degrees C generated on the flat bottom plate of the tray reactor. Using human-derived DNA containing the mitochondria genes as the amplification targets, the droplet-based PCR with magnetic reciprocative thermal cycling successfully provided the five PCR products ranging from 126 to 1,219 bp in 11 min with 30 cycles. More remarkably, the human genomic gene amplification targeting glyceraldehyde-3-phosphate dehydrogenase (GAPDH) gene was accomplished rapidly in 3.6 min with 40 cycles.
Similar articles
-
Continuous-flow polymerase chain reaction of single-copy DNA in microfluidic microdroplets.Anal Chem. 2009 Jan 1;81(1):302-6. doi: 10.1021/ac802038c. Anal Chem. 2009. PMID: 19055421
-
Rapid PCR in a continuous flow device.Lab Chip. 2004 Dec;4(6):638-45. doi: 10.1039/b406860b. Epub 2004 Oct 19. Lab Chip. 2004. PMID: 15570378
-
Temperature distribution effects on micro-CFPCR performance.Biomed Microdevices. 2008 Apr;10(2):141-52. doi: 10.1007/s10544-007-9119-6. Biomed Microdevices. 2008. PMID: 17896180
-
Microfluidic DNA amplification--a review.Anal Chim Acta. 2009 Apr 13;638(2):115-25. doi: 10.1016/j.aca.2009.02.038. Epub 2009 Mar 4. Anal Chim Acta. 2009. PMID: 19327449 Review.
-
PCR microfluidic devices for DNA amplification.Biotechnol Adv. 2006 May-Jun;24(3):243-84. doi: 10.1016/j.biotechadv.2005.10.002. Epub 2005 Dec 2. Biotechnol Adv. 2006. PMID: 16326063 Review.
Cited by
-
All-fiber all-optical quantitative polymerase chain reaction (qPCR).Sens Actuators B Chem. 2020 Nov 15;323:128681. doi: 10.1016/j.snb.2020.128681. Epub 2020 Aug 9. Sens Actuators B Chem. 2020. PMID: 32834504 Free PMC article.
-
Heterogeneous Immunoassay Using Channels and Droplets in a Digital Microfluidic Platform.Micromachines (Basel). 2019 Feb 5;10(2):107. doi: 10.3390/mi10020107. Micromachines (Basel). 2019. PMID: 30764575 Free PMC article.
-
Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface.Lab Chip. 2009 Jun 7;9(11):1567-75. doi: 10.1039/b819818g. Epub 2009 Mar 9. Lab Chip. 2009. PMID: 19458864 Free PMC article.
-
Droplet-based microsystem for multi-step bioreactions.Biomed Microdevices. 2010 Jun;12(3):533-41. doi: 10.1007/s10544-010-9410-9. Biomed Microdevices. 2010. PMID: 20204702 Free PMC article.
-
Multiplexed real-time polymerase chain reaction on a digital microfluidic platform.Anal Chem. 2010 Mar 15;82(6):2310-6. doi: 10.1021/ac902510u. Anal Chem. 2010. PMID: 20151681 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous