Environmental contamination during tracheal suction. A comparison of disposable conventional catheters with a multiple-use closed system device
- PMID: 1750600
- DOI: 10.1111/j.1365-2044.1991.tb09858.x
Environmental contamination during tracheal suction. A comparison of disposable conventional catheters with a multiple-use closed system device
Abstract
The extent of airborne environmental bacterial contamination which occurs following tracheal suction has been investigated in patients undergoing intermittent positive pressure ventilation in the intensive therapy unit. Two methods of performing suction, one using a conventional open technique and one using a closed system (Stericath), have been compared. Significantly lower levels of environmental contamination were observed when the closed system was used.
Similar articles
-
Dissemination of respiratory secretions during tracheal tube suctioning in an intensive care unit.Ann Acad Med Singap. 1999 Mar;28(2):178-82. Ann Acad Med Singap. 1999. PMID: 10497662
-
[Efficiency of novel splash-proof ventilator circuit component on VAP and the colonization of multiple-drug resistant bacteria prevention in patients undergoing mechanical ventilation: a prospective randomized controlled intervention study with 318 patients].Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017 Jan;29(1):16-20. doi: 10.3760/cma.j.issn.2095-4352.2017.01.004. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2017. PMID: 28459397 Chinese.
-
Contamination of multi-use closed tracheal suction catheters: an in-vitro study.J Hosp Infect. 1995 Nov;31(3):219-24. doi: 10.1016/0195-6701(95)90069-1. J Hosp Infect. 1995. PMID: 8586791
-
Interpretation of tracheal cultures in patients with intubation and mechanical ventilation.Am Surg. 1972 Oct;38(10):537-41. Am Surg. 1972. PMID: 4405569 No abstract available.
-
Closed versus open suctioning techniques.Minerva Anestesiol. 2002 May;68(5):360-4. Minerva Anestesiol. 2002. PMID: 12029246 Review.
Cited by
-
Tracheal suction by closed system without daily change versus open system.Intensive Care Med. 2006 Apr;32(4):538-44. doi: 10.1007/s00134-005-0057-6. Epub 2006 Mar 2. Intensive Care Med. 2006. PMID: 16511633 Clinical Trial.
-
Abnormally increased power of breathing as a complication of closed endotracheal suction catheter systems.Respir Care. 2006 Apr;51(4):423-5. Respir Care. 2006. PMID: 16569266 Free PMC article. No abstract available.
-
Ventilator-associated pneumonia in patients admitted to intensive care units, using open or closed endotracheal suctioning.Anesth Pain Med. 2014 Sep 17;4(5):e21649. doi: 10.5812/aapm.21649. eCollection 2014 Dec. Anesth Pain Med. 2014. PMID: 25729677 Free PMC article.
-
Ventilator-associated Pneumonia: Is the Dilemma Still "Open" or "Closed"?Indian J Crit Care Med. 2022 Jul;26(7):778-779. doi: 10.5005/jp-journals-10071-24249. Indian J Crit Care Med. 2022. PMID: 36864862 Free PMC article.
-
Comparing influence of intermittent subglottic secretions drainage with/without closed suction systems on the incidence of ventilator associated pneumonia.Indian J Crit Care Med. 2011 Jul;15(3):168-72. doi: 10.4103/0972-5229.84902. Indian J Crit Care Med. 2011. PMID: 22013309 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources