Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Jul;18(7):704-8.
doi: 10.1111/j.1540-8167.2007.00842.x. Epub 2007 May 15.

Reduction of AF recurrence after pulmonary vein isolation by eliminating ATP-induced transient venous re-conduction

Affiliations
Comparative Study

Reduction of AF recurrence after pulmonary vein isolation by eliminating ATP-induced transient venous re-conduction

Seiichiro Matsuo et al. J Cardiovasc Electrophysiol. 2007 Jul.

Abstract

Background: Recent evidence has suggested that the transient re-conduction of the isolated pulmonary vein (PV) induced by the intravenous injection of adenosine (dormant PV conduction) might predict the incidence of subsequent venous reconnection after the procedure, which is the main cause of the atrial fibrillation (AF) recurrence after PV isolation (PVI). We tested the hypothesis that the elimination of these dormant PV conductions by additional radiofrequency (RF) applications can improve the efficacy of the PVI.

Methods and results: One hundred forty-eight patients (124 males; mean age 53 +/- 9 years) with drug-refractory AF underwent the PVI procedure. The standard PVI was performed in 94 patients (Group A), whereas the elimination of adenosine triphosphate (ATP)-induced dormant conduction using additional RF energy was performed in addition to the standard PVI in other 54 patients (Group B). Dormant conduction was observed in 56% of the patients (30/54) in Group B and 95% of these transient re-conductions were successfully eliminated by additional RF applications (mean: 1.5 +/- 1.0 times). During the mean follow-up period of 20 months, recurrences of AF after the procedures were observed significantly less frequently in Group B (20%) than in Group A (40%) (P < 0.05).

Conclusion: The use of additional RF applications to eliminate transient PV reconnection induced by ATP injection led to a reduction of AF recurrence after PVI, most likely due to the minimization of the subsequent PV reconnection.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources