Clinical validation of the molecular BD GeneOhm StaphSR assay for direct detection of Staphylococcus aureus and methicillin-resistant Staphylococcus aureus in positive blood cultures
- PMID: 17522275
- PMCID: PMC1932973
- DOI: 10.1128/JCM.00552-07
Clinical validation of the molecular BD GeneOhm StaphSR assay for direct detection of Staphylococcus aureus and methicillin-resistant Staphylococcus aureus in positive blood cultures
Abstract
The rapid detection of Staphylococcus aureus bacteremia and a swift determination of methicillin susceptibility has serious clinical implications affecting patient mortality. This study evaluated the StaphSR assay (BD GeneOhm, San Diego, CA), a real-time PCR assay, for the identification and differentiation of methicillin-susceptible S. aureus (MSSA) and methicillin-resistant S. aureus (MRSA) from 300 positive blood cultures. The BD GeneOhm StaphSR assay was performed and interpreted according to the manufacturer's recommendations. Positive blood cultures (containing predominantly gram-positive cocci in clusters) were subcultured on 5% sheep blood agar plates. After 18 to 24 h of incubation, isolates morphologically consistent with S. aureus were presumptively identified by latex agglutination (Staphaurex Plus; Remel, Lenexa, KS). Susceptibility testing was initially performed with the Phoenix automated microbiology system (BD Diagnostics, Sparks, MD). Additional susceptibility testing of samples with discrepant results was done using BBL oxacillin screen agar (BD Diagnostics, Sparks, MD), oxacillin and cefoxitin Etests (AB Biodisk, Solna, Sweden) on Mueller-Hinton agar, an immunoassay for penicillin binding protein 2' (Denka Seiken Co., Tokyo, Japan), and mecA PCR. The sensitivity, specificity, and positive and negative predictive values of the BD GeneOhm StaphSR assay for MSSA detection were 98.9, 96.7, 93.6, and 99.5%, respectively. For the detection of MRSA, the BD GeneOhm StaphSR assay was 100% sensitive and 98.4% specific; positive and negative predictive values for MRSA detection were 92.6 and 100%, respectively. Inhibition was seen with only one sample, and the issue was resolved upon retesting. The BD GeneOhm StaphSR assay appears to be a valuable diagnostic tool for quickly differentiating bacteremia caused by MSSA and MRSA from that caused by other gram-positive cocci.
References
-
- Bishop, E. J., E. A. Grabsch, S. A. Ballard, B. Mayall, S. Xie, R. Martin, and M. L. Grayson. 2006. Concurrent analysis of nose and groin swab specimens by the IDI-MRSA PCR assay is comparable to analysis by individual-specimen PCR and routine culture assays for detection of colonization by methicillin-resistant Staphylococcus aureus. J. Clin. Microbiol. 44:2904-2908. - PMC - PubMed
-
- Carroll, K. C., A. P. Borek, C. Burger, B. Glanz, H. Bhally, S. Henciak, and D. C. Flayhart. 2006. Evaluation of the BD Phoenix automated microbiology system for identification and antimicrobial susceptibility testing of staphylococci and enterococci. J. Clin. Microbiol. 44:2072-2077. - PMC - PubMed
-
- Carroll, K. C., R. B. Leonard, P. L. Newcomb-Gayman, and D. R. Hillyard. 1996. Rapid detection of the staphylococcal mecA gene from BACTEC blood culture bottles by the polymerase chain reaction. Am. J. Clin. Pathol. 106:600-605. - PubMed
-
- Cepheid. 2003. SmartCycler II operator's manual. Cepheid, Sunny vale, CA.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical