Evaluation of the Ciba Corning Biotrack 512 coagulation monitor for the control of oral anticoagulation
- PMID: 1752987
- PMCID: PMC496638
- DOI: 10.1136/jcp.44.11.950
Evaluation of the Ciba Corning Biotrack 512 coagulation monitor for the control of oral anticoagulation
Abstract
The Ciba Corning Biotrack 512 coagulation monitor requires a minimal degree of technical expertise to operate, and is already in use for near-patient testing. This study evaluated the monitor for possible use in decentralised control of oral anticoagulant treatment. The monitor compared well with Manchester Reagent, suggesting that it could be used in areas where this thromboplastin is used for centralised control. The inability of the monitor to allow for locally determined geometric mean normal prothrombin times in the calculation of the International Normalised Ratio (INR), and possibly the high International Sensitivity Index (ISI) of the thromboplastin used with the monitor, resulted in poor comparability with some other thromboplastins, particularly Thrombotest. These problems need to be addressed if the monitor is to be used for decentralised anticoagulant control.
Similar articles
-
Effect of thromboplastin and coagulometer interaction on the precision of the International Normalised Ratio.J Clin Pathol. 1995 Jan;48(1):13-7. doi: 10.1136/jcp.48.1.13. J Clin Pathol. 1995. PMID: 7706513 Free PMC article.
-
Implications of use of low international sensitivity index thromboplastins in prothrombin time testing.Arch Pathol Lab Med. 1994 Dec;118(12):1183-7. Arch Pathol Lab Med. 1994. PMID: 7979911
-
Standardizing the prothrombin time. Calibrating coagulation instruments as well as thromboplastin.Arch Pathol Lab Med. 1993 Jun;117(6):602-5. Arch Pathol Lab Med. 1993. PMID: 8503731
-
[Prothrombin time and its standardization].Rinsho Byori. 2002 Aug;50(8):779-85. Rinsho Byori. 2002. PMID: 12373814 Review. Japanese.
-
A critical evaluation of the prothrombin time for monitoring oral anticoagulant therapy.Pathophysiol Haemost Thromb. 2003;33(1):43-51. doi: 10.1159/000071641. Pathophysiol Haemost Thromb. 2003. PMID: 12853712 Review.
Cited by
-
Oral anticoagulant therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.Chest. 2012 Feb;141(2 Suppl):e44S-e88S. doi: 10.1378/chest.11-2292. Chest. 2012. PMID: 22315269 Free PMC article. Review.
-
A Stab in the Dark? Point-of-Care Testing in the Population With Hip Fracture.Geriatr Orthop Surg Rehabil. 2015 Sep;6(3):157-9. doi: 10.1177/2151458515583087. Geriatr Orthop Surg Rehabil. 2015. PMID: 26328229 Free PMC article.
-
Primary care anticoagulant management using near patient testing.Ir J Med Sci. 2003 Jan-Mar;172(1):30-2. doi: 10.1007/BF02914783. Ir J Med Sci. 2003. PMID: 12760461
-
Evaluation of a primary care anticoagulant clinic managed by a pharmacist.BMJ. 1996 Mar 2;312(7030):560. doi: 10.1136/bmj.312.7030.560. BMJ. 1996. PMID: 8595288 Free PMC article. No abstract available.
-
Accuracy and precision of the TAS analyser for near-patient INR testing by non-pathology staff in the community.J Clin Pathol. 1998 Jan;51(1):68-72. doi: 10.1136/jcp.51.1.68. J Clin Pathol. 1998. PMID: 9577376 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical