Validation of an optical encoder during free weight resistance movements and analysis of bench press sticking point power during fatigue
- PMID: 17530976
- DOI: 10.1519/R-20406.1
Validation of an optical encoder during free weight resistance movements and analysis of bench press sticking point power during fatigue
Abstract
During the concentric movement of the bench press, there is an initial high-power push after chest contact, immediately followed by a characteristic area of low power, the so-called "sticking region." During high-intensity lifting, a decline in power can result in a failed lift attempt. The purpose of this study was to determine the validity of an optical encoder to measure power and then employ this device to determine power changes during the initial acceleration and sticking region during fatiguing repeated bench press training. Twelve subjects performed a free weight bench press, a Smith Machine back squat, and a Smith Machine 40-kg bench press throw for power validation measures. All barbell movements were simultaneously monitored using cinematography and an optical encoder. Eccentric and concentric mean and peak power were calculated using time and position data derived from each method. Validity of power measures between the video (criterion) and optical encoder scores were evaluated by standard error of the estimate (SEE) and coefficient of variation (CV). Seven subjects then performed 4 sets of 6 free weight bench press repetitions progressively increasing from 85 to 95% of their 6 repetition maximum, with each repetition continually monitored by an optical encoder. The SEE for power ranged from 3.6 to 14.4 W (CV, 1.0-3.0%; correlation, 0.97-1.00). During the free weight bench press training, peak power declined by approximately 55% (p < 0.01) during the initial acceleration phase of the final 2 repetitions of the final set. Although decreases in power of the sticking point were significant (p < 0.01), as early as repetition 5 (-40%) they reached critically low levels in the final 2 repetitions (>-95%). In conclusion, the optical encoder provided valid measures of kinetics during free weight resistance training movements. The decline in power during the initial acceleration phase appears a factor in a failed lift attempt at the sticking point.
Similar articles
-
Training leading to repetition failure enhances bench press strength gains in elite junior athletes.J Strength Cond Res. 2005 May;19(2):382-8. doi: 10.1519/R-15224.1. J Strength Cond Res. 2005. PMID: 15903379 Clinical Trial.
-
Fatigue effects upon sticking region and electromyography in a six-repetition maximum bench press.J Sports Sci. 2013;31(16):1823-30. doi: 10.1080/02640414.2013.803593. Epub 2013 Jul 23. J Sports Sci. 2013. PMID: 23879709
-
Effect of loading on unintentional lifting velocity declines during single sets of repetitions to failure during upper and lower extremity muscle actions.Int J Sports Med. 2006 Sep;27(9):718-24. doi: 10.1055/s-2005-872825. Int J Sports Med. 2006. PMID: 16944400
-
The Contribution of Muscular Fatigue and Shoulder Biomechanics to Shoulder Injury Incidence During the Bench Press Exercise: A Narrative Review.J Strength Cond Res. 2024 Dec 1;38(12):2147-2163. doi: 10.1519/JSC.0000000000004973. J Strength Cond Res. 2024. PMID: 39808810 Review.
-
Understanding and Overcoming the Sticking Point in Resistance Exercise.Sports Med. 2016 Jun;46(6):751-62. doi: 10.1007/s40279-015-0460-2. Sports Med. 2016. PMID: 26758462 Free PMC article. Review.
Cited by
-
Development and Evaluation of a Full-Waveform Resistance Training Monitoring System Based on a Linear Position Transducer.Sensors (Basel). 2023 Feb 22;23(5):2435. doi: 10.3390/s23052435. Sensors (Basel). 2023. PMID: 36904637 Free PMC article.
-
Validation of Inertial Sensor to Measure Barbell Kinematics across a Spectrum of Loading Conditions.Sports (Basel). 2020 Jun 29;8(7):93. doi: 10.3390/sports8070093. Sports (Basel). 2020. PMID: 32610449 Free PMC article.
-
A mathematical model of neuromuscular adaptation to resistance training and its application in a computer simulation of accommodating loads.Eur J Appl Physiol. 2010 Oct;110(3):523-38. doi: 10.1007/s00421-010-1526-3. Epub 2010 Jun 11. Eur J Appl Physiol. 2010. PMID: 20544357
-
Validity and Reliability of a Commercially-Available Velocity and Power Testing Device.Sports (Basel). 2018 Dec 10;6(4):170. doi: 10.3390/sports6040170. Sports (Basel). 2018. PMID: 30544687 Free PMC article.
-
A low-cost contact system to assess load displacement velocity in a resistance training machine.J Sports Sci Med. 2011 Sep 1;10(3):472-7. eCollection 2011. J Sports Sci Med. 2011. PMID: 24150620 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources