Abstract
To determine anatomical and functional changes within the first 24 hours after percutaneous coronary rotational angioplasty (PCRA-ROTABLATOR, Biophysics International, USA), we studied 5 patients (4 men) with a mean age of 55 years (range 52-59) using quantitative coronary angiography, coronary flow reserve from digitized coronary angiograms, quantitative left ventricular angiography, and 99mTechnetium-MIBI SPECT imaging before PCRA, immediately after, and 24 hours after. The minimal luminal diameter and obstruction area showed a moderate increase immediately after PCRA, with a substantial further improvement after 24 hours. The mean coronary flow reserve before PCRA and 24 hours after (1.65 +/- 0.31 vs. 1.81 +/- 0.37; p = NS) remained unchanged. Although the global ejection fraction showed slight impairment immediately after PCRA, this was restored 24 hours later. Only the contribution to regional ejection fraction in the regions supplied by the treated coronary artery attributed to the decrease of global ejection fraction. Before and after PCRA, Tc-99m MIBI tomography performed at rest revealed no perfusion defects in the myocardial regions related to the coronary arteries undergoing the intervention.
Similar articles
-
Maximal myocardial perfusion by videodensitometry in the assessment of the early and late results of coronary angioplasty: relationship with coronary artery measurements and left ventricular function at rest.Cathet Cardiovasc Diagn. 1995 Apr;34(4):301-10; discussion 311-2. doi: 10.1002/ccd.1810340206. Cathet Cardiovasc Diagn. 1995. PMID: 7621539
-
Inability of coronary blood flow reserve measurements to assess the efficacy of coronary angioplasty in the first 24 hours in unselected patients.Am Heart J. 1991 Sep;122(3 Pt 1):631-9. doi: 10.1016/0002-8703(91)90505-c. Am Heart J. 1991. PMID: 1877439
-
Functional assessment of coronary artery stenosis by doppler derived absolute and relative coronary blood flow velocity reserve in comparison with (99m)Tc MIBI SPECT.Heart. 1999 Oct;82(4):509-14. doi: 10.1136/hrt.82.4.509. Heart. 1999. PMID: 10490570 Free PMC article.
-
Simultaneous assessment of myocardial perfusion and left ventricular function during transient coronary occlusion.J Am Coll Cardiol. 1995 Jun;25(7):1529-38. doi: 10.1016/0735-1097(95)00092-i. J Am Coll Cardiol. 1995. PMID: 7759703
-
[New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].Herz. 1997 Apr;22(2):72-86. doi: 10.1007/BF03044306. Herz. 1997. PMID: 9206707 Review. German.
References
MeSH terms
LinkOut - more resources
Medical
Miscellaneous