[18F-FDG imaging by coincidence circuit SPECT with low-dose CT in preoperative assessment of pulmonary lesions]
- PMID: 17533745
[18F-FDG imaging by coincidence circuit SPECT with low-dose CT in preoperative assessment of pulmonary lesions]
Abstract
Objective: To assess the clinical diagnostic value of 18F-FDG imaging by coincidence circuit SPECT with low-dose CT in differential diagnosis of pulmonary lesions and mediastinal lymph node involvement, which can not be definitely diagnosed based on regular CT image in patients with non-small-cell lung cancer (NSCLC).
Methods: By using GE-Millennium VG with Hawkeye, 18F-FDG imaging was carried out in 48 patients with suspected lung cancer. Clinical value of 18F-FDG imaging for diagnosing malignancy was evaluated through comparison with the final pathological results. Mediastinal lymph node involvement was also assessed through lesion-by-lesion comparison with pathologic results in 74 lymph node regions from 24 patients.
Results: Final pathologic diagnoses of these patients were 36 malignancies consisting of 20 adenocarcinomas, 12 squamous cell carcinomas, 3 small cell carcinomas and I large cell carcinoma; 12 benign tumors including 6 pneumonias, 2 tuberculosis, 2 hamatomas, 1 cyst and 1 neurofibroma. Of 48 patients, uptake of 18F-FDG in the chest was found to be abnormal in 40. Correct diagnosis were made in 34 malignancies and 6 false positive lesions were excluded based on morphology and 18F-FDG uptake status of the lesion. There were 6 false positive and 2 false negative cases. Furthermore, extrathoracic metastases which were not showed on previous CT image in 4 patients including one in the adrenal gland and 3 in the bone were detected by 18F-FDG imaging. The sensitivity, specificity and accuracy of the 18F-FDG imaging for differentiating malignant tumor from benign was 94.4%, 50.0% and 83.3%, respectively. Squamous cell carcinoma was found to uptake more FDG than adenocarcinoma. For determination of mediastinal lymph node involvement, the sensitivity, specificity and accuracy of 18F-FDG imaging was 57.9% , 90.9% and 82.4%, respectively through lesion-by-lesion comparison; whereas, which was 61.5%, 81.8% and 70.8%, respectively, based on case-by-case comparison.
Conclusion: 18F-FDG imaging by coincidence circuit SPECT with low-dose CT is quite helpful in differential diagnosis for patient with undetermined lesion on regular CT image, but it is limited for staging of lung cancer in the patients with non-small cell lung cancer.
Similar articles
-
[The role of (18)F-FDG DHC SPECT-CT in the diagnosis and staging for lung cancer].Zhonghua Zhong Liu Za Zhi. 2008 Dec;30(12):933-6. Zhonghua Zhong Liu Za Zhi. 2008. PMID: 19173997 Chinese.
-
Mediastinal lymph node involvement in non-small cell lung cancer: evaluation with 99mTc-tetrofosmin SPECT and comparison with CT.J Nucl Med. 2003 Aug;44(8):1219-24. J Nucl Med. 2003. PMID: 12902410 Clinical Trial.
-
[Comparison of 18F-FDG coincidence SPECT imaging and computed tomography in the initial staging and therapeutic evaluation of lymphomas].Zhonghua Zhong Liu Za Zhi. 2007 Jul;29(7):536-9. Zhonghua Zhong Liu Za Zhi. 2007. PMID: 18069637 Chinese.
-
Nuclear medicine imaging in tuberculosis using commercially available radiopharmaceuticals.Nucl Med Commun. 2012 Jun;33(6):581-90. doi: 10.1097/MNM.0b013e3283528a7c. Nucl Med Commun. 2012. PMID: 22422098 Review.
-
Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography.Eur J Cardiothorac Surg. 2009 Sep;36(3):440-5. doi: 10.1016/j.ejcts.2009.04.003. Epub 2009 May 22. Eur J Cardiothorac Surg. 2009. PMID: 19464906 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical