. 2007 May;52(2):14-7.
doi: 10.1258/rsmsmj.52.2.14.

The use of the artificial urinary sphincter in the West of Scotland: a single centre 10-year experience

Affiliations

The use of the artificial urinary sphincter in the West of Scotland: a single centre 10-year experience

A K Ramsay et al. Scott Med J. 2007 May.

Abstract

Background: The artificial urinary sphincter (AUS) has been used successfully to treat sphincter weakness incontinence in males over the past 30 years. Postoperative complications are well-recognised, but patient satisfaction remains high.

Methods: We performed a retrospective single centre study of all patients who had an artificial urinary sphincter inserted over a 10-year period. We assessed patient satisfaction and continence post operatively as well as complication rate and need for revision or replacement surgery.

Results: Thirty-eight male patients (mean age 57 years) and 1 female patient had an AMS 800 (American Medical systems) AUS inserted between 1995 and 2005. Five (13%) patients have required replacement surgery to date. Male patients were divided into two groups according to the aetiology of their incontinence: neuropathic (n = 11) and non-neuropathic (n = 27). Social continence was achieved in all patients. Three (11%) non-neuropathic patients developed complications. Revision surgery was undertaken in 4 (15%) of non-neuropathic patients and in 1 (9%) neuropathic patient. The mean lifespan of the AUS in patients who required further surgery is 6.6 years.

Conclusion: For patients with severe sphincter weakness incontinence the AMS 800 AUS is a safe and reliable solution. Our results are comparable with previous published studies of larger patient numbers from dedicated reconstructive units.