Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Jun 1;25(16):2262-9.
doi: 10.1200/JCO.2006.09.6297.

Superiority of fluorodeoxyglucose positron emission tomography to other functional imaging techniques in the evaluation of metastatic SDHB-associated pheochromocytoma and paraganglioma

Affiliations

Superiority of fluorodeoxyglucose positron emission tomography to other functional imaging techniques in the evaluation of metastatic SDHB-associated pheochromocytoma and paraganglioma

Henri J L M Timmers et al. J Clin Oncol. .

Abstract

Purpose: Germline mutations of the gene encoding subunit B of the mitochondrial enzyme succinate dehydrogenase (SDHB) predispose to malignant paraganglioma (PGL). Timely and accurate localization of these aggressive tumors is critical for guiding optimal treatment. Our aim is to evaluate the performance of functional imaging modalities in the detection of metastatic lesions of SDHB-associated PGL.

Patients and methods: Sensitivities for the detection of metastases were compared between [18F]fluorodopamine ([18F]FDA) and [18F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET), iodine-123- (123I) and iodine-131 (131I) -metaiodobenzylguanidine (MIBG), 111In-pentetreotide, and Tc-99m-methylene diphosphonate bone scintigraphy in 30 patients with SDHB-associated PGL. Computed tomography (CT) and magnetic resonance imaging (MRI) served as standards of reference.

Results: Twenty-nine of 30 patients had metastatic lesions. In two patients, obvious metastatic lesions on functional imaging were missed by CT and MRI. Sensitivity according to patient/body region was 80%/65% for 123I-MIBG and 88%/70% for [18F]FDA-PET. False-negative results on 123I-MIBG scintigraphy and/or [18F]FDA-PET were not predicted by genotype or biochemical phenotype. [18F]FDG-PET yielded a by patient/by body region sensitivity of 100%/97%. At least 90% of regions that were false negative on 123I-MIBG scintigraphy or [18F]FDA-PET were detected by [18F]FDG-PET. In two patients, 111In-pentetreotide scintigraphy detected liver lesions that were negative on other functional imaging modalities. Sensitivities were similar before and after chemotherapy or 131I-MIBG treatment, except for a trend toward lower post- (60%/41%) versus pretreatment (80%/65%) sensitivity of 123I-MIBG scintigraphy.

Conclusion: With a sensitivity approaching 100%, [18F]FDG-PET is the preferred functional imaging modality for staging and treatment monitoring of SDHB-related metastatic PGL.