Influence on posterior capsule opacification and visual function of intraocular lens optic material
- PMID: 17553447
- DOI: 10.1016/j.ajo.2007.04.044
Influence on posterior capsule opacification and visual function of intraocular lens optic material
Abstract
Purpose: To examine the influence of optic material on posterior capsule opacification (PCO) by comparing PCO and visual functions between eyes with an acrylic intraocular lens (IOLs) and those with a silicone IOL of the same optic design and with the same haptics.
Design: Randomized clinical trial.
Methods: One hundred patients scheduled for phacoemulsification surgery underwent implantation of an acrylic IOL (AMO Sensar; AR40e) in one eye and implantation of a silicone IOL (ClariFlex) of the same optic design and loops in the fellow eye. Eighty-nine patients (89%) remained for analysis. The PCO value was measured using the Scheimpflug videophotography system at one, three, six, 12, 18, 24, 30, and 36 months postoperatively. The incidence of eyes that required a neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy was examined; visual acuity and contrast sensitivity with and without a glare source were also evaluated.
Results: The mean PCO value did not increase significantly during follow-up in either the acrylic or silicone IOL group. When comparing the groups, no statistically significant difference was found in the PCO or in the incidence of Nd:YAG capsulotomy, although both tended to be slightly better in the silicone group than in the acrylic group. There was also no significant difference between the groups in visual acuity or in photopic and mesopic contrast sensitivity with or without glare.
Conclusions: When acrylic and silicone IOLs are of the same optic design and with the same haptics, the optic material does not influence the development of PCO enough to impair visual function.
Similar articles
-
Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge.Ophthalmology. 2005 Sep;112(9):1550-6. doi: 10.1016/j.ophtha.2005.03.024. Ophthalmology. 2005. PMID: 16005976 Clinical Trial.
-
Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification.Ophthalmology. 2008 May;115(5):830-8. doi: 10.1016/j.ophtha.2007.06.037. Epub 2007 Oct 26. Ophthalmology. 2008. PMID: 17964657
-
Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery.Am J Ophthalmol. 2009 Apr;147(4):683-690.e2. doi: 10.1016/j.ajo.2008.11.006. Epub 2009 Feb 8. Am J Ophthalmol. 2009. PMID: 19201391 Clinical Trial.
-
Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: a meta-analysis.Am J Ophthalmol. 2007 Mar;143(3):428-36. doi: 10.1016/j.ajo.2006.11.045. Epub 2006 Dec 28. Am J Ophthalmol. 2007. PMID: 17224119
-
Complications of cataract and refractive surgery: a clinicopathological documentation.Trans Am Ophthalmol Soc. 2001;99:95-107; discussion 107-9. Trans Am Ophthalmol Soc. 2001. PMID: 11797325 Free PMC article. Review.
Cited by
-
Interventions for preventing posterior capsule opacification.Cochrane Database Syst Rev. 2010 Feb 17;2010(2):CD003738. doi: 10.1002/14651858.CD003738.pub3. Cochrane Database Syst Rev. 2010. PMID: 20166069 Free PMC article.
-
Posterior Capsule Opacification after Cataract Surgery via Implantation with Hydrophobic Acrylic Lens Compared with Silicone Intraocular Lens: A Systematic Review and Meta-Analysis.J Ophthalmol. 2022 Feb 25;2022:3570399. doi: 10.1155/2022/3570399. eCollection 2022. J Ophthalmol. 2022. PMID: 35251708 Free PMC article. Review.
-
Intraocular lenses for the treatment of age-related cataracts: an evidence-based analysis.Ont Health Technol Assess Ser. 2009;9(15):1-62. Epub 2009 Oct 1. Ont Health Technol Assess Ser. 2009. PMID: 23074519 Free PMC article.
-
Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics.J Clin Med. 2021 Jul 24;10(15):3268. doi: 10.3390/jcm10153268. J Clin Med. 2021. PMID: 34362052 Free PMC article.
-
Effect of a capsular tension ring on prevention of intraocular lens decentration and tilt and on anterior capsule contraction after cataract surgery.Jpn J Ophthalmol. 2008 Sep-Oct;52(5):363-367. doi: 10.1007/s10384-008-0570-6. Epub 2008 Nov 11. Jpn J Ophthalmol. 2008. PMID: 18991036
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical