Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 May-Jun;32(3):251-60.
doi: 10.2341/06-70.

Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro

Affiliations
Comparative Study

Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro

Marianne Federlin et al. Oper Dent. 2007 May-Jun.

Abstract

This in vitro study tested the effects of two different ceramic thicknesses, two preparation designs and two different luting agents on the marginal integrity and fracture resistance of partial ceramic crowns (PCC). Eighty extracted human molars were prepared according to the following preparation designs: a) Coverage of functional cusps/butt joint (n=40), b) Horizontal reduction of functional cusps (n=40). PCC (Vita Mark II, Cerec3 System) were fabricated and the ceramic thickness of the functional cusps was adjusted to (1): 0.5-1.0 mm and (2): 1.5-2.0 mm. PCC were adhesively luted to the cavities with either Excite/VariolinkII (VL) or RelyX Unicem (RX). The specimens were exposed to thermocycling and central mechanical loading (5000 x 5 degrees C-55 degrees C; 30 second/cycle; 50,0000 x 72.5N, 1.6Hz). Marginal integrity was assessed by evaluating dye penetration (fuchsine) on multiple sections in the bucco-oral direction by relating the actual penetration distance to the maximal length of the corresponding cavity wall (100%). Restoration/luting agent (RL)--and tooth/luting agent (TL) interfaces were evaluated separately. The data were statistically analyzed with the Mann Whitney U-test and the Error Rates Method (ERM), and the fracture rates were analyzed with the chi2-test. Dye penetration data indicated that ceramic thickness and luting agent had a statistically significant influence upon marginal integrity in general, irrespective of all other parameters (ERM): RX showed significantly lower microleakage along the RL interface than VL. VL revealed significantly lower microleakage at the TL interface than RX. Fifteen PCC of group 1 (0.5-1.0 mm) and two PCC of group 2 (1.5-2.0 mm) were fractured after thermocycling and central mechanical loading, with the difference being statistically significant. PCC fabricated from industrially sintered feldspathic ceramic should have at least a thickness of 1.5-2.0 mm in stress-bearing areas.

PubMed Disclaimer

LinkOut - more resources