Nonparametric ROC and LROC analysis
- PMID: 17555237
- DOI: 10.1118/1.2717407
Nonparametric ROC and LROC analysis
Abstract
In this paper we review several results of the nonparametric receiver operating characteristic (ROC) analysis and present an extension to the nonparametric localization ROC (LROC) analysis. Equations for the estimation of the area under the characteristic curve and for the variance calculations are derived. Expressions for the choice of the optimal ratio between the number of signal-absent and signal-present image samples are also presented. The results can be applied both with continuous or discrete scoring scales. The simulation studies carried out validate the theoretical derivations and show that the LROC analysis is considerably more sensitive than the ROC analysis.
Similar articles
-
Nonparametric signal detectability evaluation using an exponential transformation of the FROC curve.Med Phys. 2011 Oct;38(10):5690-702. doi: 10.1118/1.3633938. Med Phys. 2011. PMID: 21992384
-
Receiver Operating Characteristic (ROC) Analysis of Image Search-and-Localize Tasks.Acad Radiol. 2020 Dec;27(12):1742-1750. doi: 10.1016/j.acra.2019.12.020. Epub 2020 Feb 5. Acad Radiol. 2020. PMID: 32033862
-
ROC and localization ROC analyses of lesion detection in whole-body FDG PET: effects of acquisition mode, attenuation correction and reconstruction algorithm.J Nucl Med. 1999 Dec;40(12):2043-52. J Nucl Med. 1999. PMID: 10616885
-
Receiver operating characteristic analysis: a tool for the quantitative evaluation of observer performance and imaging systems.J Am Coll Radiol. 2006 Jun;3(6):413-22. doi: 10.1016/j.jacr.2006.02.021. J Am Coll Radiol. 2006. PMID: 17412096 Review.
-
Receiver operating characteristic (ROC) curve: practical review for radiologists.Korean J Radiol. 2004 Jan-Mar;5(1):11-8. doi: 10.3348/kjr.2004.5.1.11. Korean J Radiol. 2004. PMID: 15064554 Free PMC article. Review.
Cited by
-
Localization of liver lesions in abdominal CT imaging: II. Mathematical model observer performance correlates with human observer performance for localization of liver lesions in abdominal CT imaging.Phys Med Biol. 2019 May 10;64(10):105012. doi: 10.1088/1361-6560/ab1a62. Phys Med Biol. 2019. PMID: 30995626 Free PMC article.
-
Model for the detection of signals in images with multiple suspicious locations.Med Phys. 2008 Dec;35(12):5565-74. doi: 10.1118/1.3002413. Med Phys. 2008. PMID: 19175114 Free PMC article.
-
A nonparametric procedure for comparing the areas under correlated LROC curves.IEEE Trans Med Imaging. 2012 Nov;31(11):2050-61. doi: 10.1109/TMI.2012.2205015. Epub 2012 Jun 18. IEEE Trans Med Imaging. 2012. PMID: 22736638 Free PMC article.
-
Effect of Using 2mm Voxels on Observer Performance for PET Lesion Detection.IEEE Trans Nucl Sci. 2016 Jun;63(3):1359-1366. doi: 10.1109/TNS.2016.2518177. Epub 2016 Apr 28. IEEE Trans Nucl Sci. 2016. PMID: 27499550 Free PMC article.
-
New developments in observer performance methodology in medical imaging.Semin Nucl Med. 2011 Nov;41(6):401-18. doi: 10.1053/j.semnuclmed.2011.07.001. Semin Nucl Med. 2011. PMID: 21978444 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources