A fast algorithm for gamma evaluation in 3D
- PMID: 17555246
- DOI: 10.1118/1.2721657
A fast algorithm for gamma evaluation in 3D
Abstract
The gamma-evaluation method is a tool by which dose distributions can be compared in a quantitative manner combining dose-difference and distance-to-agreement criteria. Since its introduction, the gamma evaluation has been used in many studies and is on the verge of becoming the preferred dose distribution comparison method, particularly for intensity-modulated radiation therapy (IMRT) verification. One major disadvantage, however, is its long computation time, which especially applies to the comparison of three-dimensional (3D) dose distributions. We present a fast algorithm for a full 3D gamma evaluation at high resolution. Both the reference and evaluated dose distributions are first resampled on the same grid. For each point of the reference dose distribution, the algorithm searches for the best point of agreement according to the gamma method in the evaluated dose distribution, which can be done at a subvoxel resolution. Speed, computer memory efficiency, and high spatial resolution are achieved by searching around each reference point with increasing distance in a sphere, which has a radius of a chosen maximum search distance and is interpolated "on-the-fly" at a chosen sample step size. The smaller the sample step size and the larger the differences between the dose distributions, the longer the gamma evaluation takes. With decreasing sample step size, statistical measures of the 3D gamma distribution converge. Two clinical examples were investigated using 3% of the prescribed dose as dose-difference and 0.3 cm as distance-to-agreement criteria. For 0.2 cm grid spacing, the change in gamma indices was negligible below a sample step size of 0.02 cm. Comparing the full 3D gamma evaluation and slice-by-slice 2D gamma evaluations ("2.5D") for these clinical examples, the gamma indices improved by searching in full 3D space, with the average gamma index decreasing by at least 8%.
Similar articles
-
Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine.Radiat Oncol. 2015 Apr 11;10:85. doi: 10.1186/s13014-015-0387-7. Radiat Oncol. 2015. PMID: 25885567 Free PMC article.
-
Development of methods for beam angle optimization for IMRT using an accelerated exhaustive search strategy.Int J Radiat Oncol Biol Phys. 2004 Nov 15;60(4):1325-37. doi: 10.1016/j.ijrobp.2004.06.007. Int J Radiat Oncol Biol Phys. 2004. PMID: 15519806
-
A nonvoxel-based dose convolution/superposition algorithm optimized for scalable GPU architectures.Med Phys. 2014 Oct;41(10):101711. doi: 10.1118/1.4895822. Med Phys. 2014. PMID: 25281950
-
Challenges in calculation of the gamma index in radiotherapy - Towards good practice.Phys Med. 2017 Apr;36:1-11. doi: 10.1016/j.ejmp.2017.03.001. Epub 2017 Mar 14. Phys Med. 2017. PMID: 28410677 Review.
-
Treatment plan verification: A review on the comparison of dose distributions.Phys Med. 2019 Nov;67:107-115. doi: 10.1016/j.ejmp.2019.10.029. Epub 2019 Nov 6. Phys Med. 2019. PMID: 31706146 Review.
Cited by
-
Three-dimensional dosimetry of TomoTherapy by MRI-based polymer gel technique.J Appl Clin Med Phys. 2010 Sep 14;12(1):3273. doi: 10.1120/jacmp.v12i1.3273. J Appl Clin Med Phys. 2010. PMID: 21330972 Free PMC article.
-
Validation of a quick three-dimensional dose verification system for pre-treatment IMRT QA.Radiol Phys Technol. 2015 Jan;8(1):73-80. doi: 10.1007/s12194-014-0294-x. Epub 2014 Sep 27. Radiol Phys Technol. 2015. PMID: 25261343
-
Modeling of Gamma Index for Prediction of Pretreatment Quality Assurance in Stereotactic Body Radiation Therapy of the Liver.J Med Phys. 2024 Apr-Jun;49(2):232-239. doi: 10.4103/jmp.jmp_176_23. Epub 2024 Jun 25. J Med Phys. 2024. PMID: 39131435 Free PMC article.
-
Numerical solutions of the γ-index in two and three dimensions.Phys Med Biol. 2012 Nov 7;57(21):6981-97. doi: 10.1088/0031-9155/57/21/6981. Epub 2012 Oct 9. Phys Med Biol. 2012. PMID: 23044713 Free PMC article.
-
Systematic evaluation of spatial resolution and gamma criteria for quality assurance with detector arrays in stereotactic radiosurgery.J Appl Clin Med Phys. 2024 Feb;25(2):e14274. doi: 10.1002/acm2.14274. Epub 2024 Jan 24. J Appl Clin Med Phys. 2024. PMID: 38265979 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical