Trace element removal during in vitro and in vivo continuous haemodialysis
- PMID: 17556411
- DOI: 10.1093/ndt/gfm352
Trace element removal during in vitro and in vivo continuous haemodialysis
Abstract
Background: Continuous renal replacement therapy (CRRT) increasingly is being used to treat critically ill patients with renal disease. CRRT removes waste products but also nutrients. Our understanding of trace element CRRT clearance has been limited by poor assay sensitivity. The development of inductively coupled plasma mass spectrometry (ICP-MS) allows for the measurement of CRRT trace element removal.
Methods: Continuous venovenous haemodialysis (CVVHD) transmembrane clearances of trace elements and urea were assessed using a bovine blood-based in vitro model using two different haemodialyser types. These findings were validated in 10 critically ill adult patients receiving continuous venovenous haemodiafiltration (CVVHDF). Calculated daily trace element loss was compared with a typical dose of daily trace element supplementation.
Results: The mean +/- SD in vitro CVVHD transmembrane clearances (ml/min) for the polysulfone haemodialyser were chromium 0.97 +/- 0.23, copper 0.47 +/- 0.18, manganese 4.6 +/- 3.6, selenium 1.2 +/- 0.63 and zinc 2.3 +/- 0.32 and for the cellulose diacetate haemodialyser chromium 1.54 +/- 0.91, copper 0.21 +/- 0.07, manganese 7.8 +/- 4.1, selenium 0.76 +/- 0.39 and zinc 2.7 +/- 0.37. The in vivo CVVHDF transmembrane clearances (ml/min) were chromium 5.4 +/- 2.4, copper 0.45 +/- 0.33, manganese 1.9 +/- 4.6, selenium 1.6 +/- 1.2, and zinc 4.0 +/- 1.3.
Conclusion: ICP-MS assays detected the five trace elements in the effluent of CVVHDF patients. Trace element CVVHD transmembrane clearance estimates for our in vitro model were supported by the in vivo CVVHDF findings. Calculated daily trace element loss attributed to CVVHD and CVVHDF with dialysate flow rates of 33.3 ml/min is less than what is provided in a daily dose of a trace element supplementation product.
Comment in
-
An understanding of trace metal physiology as an aid to interpretation of clearance studies by artificial organs.Nephrol Dial Transplant. 2008 Apr;23(4):1462; author reply 1462-3. doi: 10.1093/ndt/gfm820. Epub 2007 Nov 19. Nephrol Dial Transplant. 2008. PMID: 18029373 No abstract available.
Similar articles
-
Trace element loss in urine and effluent following traumatic injury.JPEN J Parenter Enteral Nutr. 2008 Mar-Apr;32(2):129-39. doi: 10.1177/0148607108314762. JPEN J Parenter Enteral Nutr. 2008. PMID: 18407905
-
In vitro clearance of trace elements via continuous renal replacement therapy.J Ren Nutr. 2004 Oct;14(4):214-9. J Ren Nutr. 2004. PMID: 15483781
-
[The effects of dialysate and ultrafiltration flow rate on solute clearance during continuous renal replacement therapy].Zhonghua Nei Ke Za Zhi. 2001 Mar;40(3):183-6. Zhonghua Nei Ke Za Zhi. 2001. PMID: 11798577 Chinese.
-
Technical and clinical aspects of spectrometric analysis of trace elements in clinical samples.Clin Lab Med. 1998 Dec;18(4):615-29. Clin Lab Med. 1998. PMID: 9891602 Review.
-
Dosing patterns for continuous renal replacement therapy at a large academic medical center in the United States.J Crit Care. 2002 Dec;17(4):246-50. doi: 10.1053/jcrc.2002.36757. J Crit Care. 2002. PMID: 12501152 Review.
Cited by
-
Etanercept clearance during an in vitro model of continuous venovenous hemofiltration.Blood Purif. 2009;28(4):348-53. doi: 10.1159/000232936. Epub 2009 Sep 1. Blood Purif. 2009. PMID: 19729904 Free PMC article.
-
Longitudinal hemodiafilter performance in modeled continuous renal replacement therapy.Blood Purif. 2011;32(2):82-8. doi: 10.1159/000324191. Epub 2011 Mar 2. Blood Purif. 2011. PMID: 21372565 Free PMC article.
-
Bench-to-bedside review: metabolism and nutrition.Crit Care. 2008;12(4):222. doi: 10.1186/cc6945. Epub 2008 Aug 19. Crit Care. 2008. PMID: 18768091 Free PMC article. Review.
-
Continuous venovenous hemodiafiltration trace element clearance in pediatric patients: a case series.Pediatr Nephrol. 2009 Apr;24(4):807-13. doi: 10.1007/s00467-008-1083-8. Epub 2009 Jan 21. Pediatr Nephrol. 2009. PMID: 19156445
-
Vitamin and trace element deficiencies in the pediatric dialysis patient.Pediatr Nephrol. 2018 Jul;33(7):1133-1143. doi: 10.1007/s00467-017-3751-z. Epub 2017 Jul 27. Pediatr Nephrol. 2018. PMID: 28752387 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical