Cannulating in haemodialysis: rope-ladder or buttonhole technique?
- PMID: 17557776
- DOI: 10.1093/ndt/gfm043
Cannulating in haemodialysis: rope-ladder or buttonhole technique?
Abstract
Background: The standard technique for fistula cannulation, the rope-ladder technique, is problematic for patients with short fistula lengths and for patients in whom the fistula is difficult to cannulate. The buttonhole technique, cannulation of exactly the same site, offers the advantage of an easy cannulation procedure. However, it can be used only in native fistulas and cannulation is preferably executed by a 'single-sticker'. This study was conducted to compare these cannulation techniques using objective parameters.
Methods: We introduced the buttonhole technique for self-cannulating home haemodialysis patients and compared it with baseline data obtained with the rope-ladder technique. Thirty-three patients with a native arteriovenous fistula were observed prospectively during 18 months on the following parameters: cannulating ease, number of bad sticks, pain, time of compression after cannula removal, bleeding, infectious complications and aneurysm formation.
Results: With the buttonhole method, cannulating ease improved distinctly, which was especially favourable in patients with a short fistula vein. Reported cannulation pain did not change significantly. The incidence of bad sticks decreased significantly, as well as time of compression after cannula removal, without increased incidence of bleeding. Three patients developed a local skin infection of their buttonhole during the study, after which the disinfection routine prior to cannulation was changed.
Conclusions: Compared with the rope-ladder technique, the buttonhole method offers the advantage of an easier cannulation procedure with less bad sticks, which has a special benefit for patients with limited access cannulation sites or with a fistula which is difficult to cannulate. Prolonged compression times or re-bleeding episodes did not occur, but precautions have to be taken in order to prevent infectious complications. The buttonhole method can contribute considerably to the cannulating ease of self-cannulating patients, thus providing a better quality of life.
Comment in
-
Utility of the buttonhole cannulation method for hemodialysis patients with arteriovenous fistulas.Nat Clin Pract Nephrol. 2007 Dec;3(12):648-9. doi: 10.1038/ncpneph0641. Epub 2007 Oct 16. Nat Clin Pract Nephrol. 2007. PMID: 17940521 No abstract available.
Similar articles
-
Buttonhole needling of haemodialysis arteriovenous fistulae results in less complications and interventions compared to the rope-ladder technique.Nephrol Dial Transplant. 2010 Jan;25(1):225-30. doi: 10.1093/ndt/gfp420. Epub 2009 Aug 29. Nephrol Dial Transplant. 2010. PMID: 19717827
-
Infectious complications following conversion to buttonhole cannulation of native arteriovenous fistulas: a quality improvement report.Am J Kidney Dis. 2011 Mar;57(3):442-8. doi: 10.1053/j.ajkd.2010.10.045. Epub 2011 Jan 8. Am J Kidney Dis. 2011. PMID: 21216513
-
A simple method to create buttonhole cannulation tracks in a busy hemodialysis unit.Hemodial Int. 2009 Jul;13(3):316-21. doi: 10.1111/j.1542-4758.2009.00373.x. Epub 2009 Jun 8. Hemodial Int. 2009. PMID: 19515069
-
Con: Buttonhole cannulation of arteriovenous fistulae.Nephrol Dial Transplant. 2016 Apr;31(4):525-8. doi: 10.1093/ndt/gfw030. Epub 2016 Mar 17. Nephrol Dial Transplant. 2016. PMID: 26994295 Review.
-
The buttonhole technique for fistula cannulation: pros and cons.Curr Opin Nephrol Hypertens. 2013 Nov;22(6):629-36. doi: 10.1097/MNH.0b013e328365ae9e. Curr Opin Nephrol Hypertens. 2013. PMID: 24076555 Review.
Cited by
-
Buttonhole versus Stepladder Cannulation for Home Hemodialysis: A Multicenter, Randomized, Pilot Trial.Clin J Am Soc Nephrol. 2019 Mar 7;14(3):403-410. doi: 10.2215/CJN.08310718. Epub 2019 Jan 18. Clin J Am Soc Nephrol. 2019. PMID: 30659057 Free PMC article. Clinical Trial.
-
Comparison of the Effects of Hegu Point Ice Massage and 2% Lidocaine Gel on Arteriovenous Fistula Puncture-Related Pain in Hemodialysis Patients: A Randomized Controlled Trial.J Caring Sci. 2017 Jun 1;6(2):141-151. doi: 10.15171/jcs.2017.014. eCollection 2017 Jun. J Caring Sci. 2017. PMID: 28680868 Free PMC article.
-
Risk of Vascular Access Infection Associated With Buttonhole Cannulation of Fistulas: Data From the National Healthcare Safety Network.Am J Kidney Dis. 2020 Jul;76(1):82-89. doi: 10.1053/j.ajkd.2019.11.006. Epub 2020 Mar 6. Am J Kidney Dis. 2020. PMID: 32151430 Free PMC article.
-
Clinical, patient-related, and economic outcomes of home-based high-dose hemodialysis versus conventional in-center hemodialysis.Int J Nephrol Renovasc Dis. 2016 Jul 5;9:151-9. doi: 10.2147/IJNRD.S89411. eCollection 2016. Int J Nephrol Renovasc Dis. 2016. PMID: 27462173 Free PMC article. Review.
-
Staphylococcus aureus bacteremia and buttonhole cannulation: long-term safety and efficacy of mupirocin prophylaxis.Clin J Am Soc Nephrol. 2010 Jun;5(6):1047-53. doi: 10.2215/CJN.00280110. Epub 2010 Apr 22. Clin J Am Soc Nephrol. 2010. PMID: 20413438 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials