In vitro evaluation of a high-efficiency leukocyte adherence filter
- PMID: 1756191
- DOI: 10.1007/BF01709651
In vitro evaluation of a high-efficiency leukocyte adherence filter
Abstract
In view of the currently available data, prevention of alloimmunization requires filters with higher efficiency to achieve a reduction in the number of leukocytes below 10 million per transfusion. Two versions (Pall PL-100 and PL-50) of the new generation leukocyte-depletion filters were studied. Single donor (SDPC)- and pooled multiple donor (MDPC) platelets were run in parallel. At a flow rate of 10 ml/min, the PL-100 filter was shown to effectively reduce the number of residual leukocytes to far below the critical immunogenic threshold of 10 million in all SDPC units and in 77% of MDPC units. Apheresis platelets appear not only to be better depleted than pooled multiple donor platelets, but also to have a better post-filtration platelet recovery (96% versus 84%). The efficiency of the smaller version of the filter (Pall-50) was higher than that of the Pall-100 filter for both single and pooled multiple donor platelet concentrates (PC). Leukocytes were absent in more than 92% of units in both types of concentrates. The maximal number of detected leukocytes was 2.2 million in a pool of 6 units. The outcome of filtration of 5-day-old pooled platelets was less favorable than filtration of 1- or 2-day-old pooled platelets, indicating that filtration soon after preparation is preferred to filtration after storage. Post-filtration platelet integrity, activation state, function, and morphology were all well preserved in both single and multiple PCs.
Similar articles
-
Evaluation of leukocyte-depleted platelet concentrates obtained by in-line filtration.Vox Sang. 2000;78(4):235-41. doi: 10.1159/000031187. Vox Sang. 2000. PMID: 10895097
-
Comparison of four filters for leukocyte depletion of single donor plateletapheresis products.Transfus Sci. 1993 Apr;14(2):211-5. doi: 10.1016/0955-3886(93)90033-Q. Transfus Sci. 1993. PMID: 10148614
-
[Performance of Pall filters (RC 100 and PL 100) for the removal of leukocytes from red-cell concentrates and platelets].Rev Fr Transfus Hemobiol. 1989 Sep;32(4):307-22. doi: 10.1016/s1140-4639(89)80006-1. Rev Fr Transfus Hemobiol. 1989. PMID: 2818773 French.
-
Leukodepletion blood filters: filter design and mechanisms of leukocyte removal.Transfus Med Rev. 1993 Apr;7(2):65-77. doi: 10.1016/s0887-7963(93)70125-x. Transfus Med Rev. 1993. PMID: 8481601 Review.
-
Leukocyte depletion for safe blood transfusion.Biotechnol J. 2009 Aug;4(8):1140-51. doi: 10.1002/biot.200800182. Biotechnol J. 2009. PMID: 19418471 Review.
Cited by
-
A high-throughput microfluidic approach for 1000-fold leukocyte reduction of platelet-rich plasma.Sci Rep. 2016 Oct 24;6:35943. doi: 10.1038/srep35943. Sci Rep. 2016. PMID: 27775049 Free PMC article.
References
MeSH terms
LinkOut - more resources
Other Literature Sources