. 2007 Aug;14(8):1050-2.
doi: 10.1128/CVI.00465-06. Epub 2007 Jun 13.

Clinical evaluation of the SD Bioline influenza virus antigen test for rapid detection of influenza viruses A and B in children and adults during the influenza season

Affiliations

Clinical evaluation of the SD Bioline influenza virus antigen test for rapid detection of influenza viruses A and B in children and adults during the influenza season

Young Yoo et al. Clin Vaccine Immunol. 2007 Aug.

Abstract

The performance of the SD Bioline rapid antigen test kit for influenza virus detection was evaluated with 295 respiratory specimens during the influenza season. The overall sensitivity and specificity of the SD Bioline test were 61.9% and 96.8% for the influenza A virus antigen and 54.5% and 100% for the influenza B virus antigen, respectively. The results were consistent with peak influenza activities.

PubMed Disclaimer

Figures

FIG. 1.
FIG. 1.
Detection of influenza viruses by culture and by the SD Bioline rapid antigen test in conjunction with an epidemic curve with two peaks of influenza activity based on the report from the KISS for the 2005-to-2006 season.,formula image influenza A reported by the KISS;formula image, influenza B reported by the KISS; □, influenza A virus detected by culture; formula image, influenza B virus detected by culture; —, influenza A virus detected by the SD Bioline test; ----, influenza B virus detected by the SD Bioline test.

Similar articles

Cited by

References

    1. Agoritsas, K., K. Mack, B. K. Bonsu, D. Goodman, D. Salamon, and M. J. Marcon. 2006. Evaluation of the Quidel QuickVue test for detection of influenza A and B viruses in the pediatric emergency medicine setting by use of three specimen collection methods. J. Clin. Microbiol. 44:2638-2641. - PMC - PubMed
    1. Barenfanger, J., C. Drake, T. Mueller, T. Troutt, J. O'Brien, and K. Guttman. 2001. R-Mix cells are faster, at least as sensitive and marginally more costly than conventional cell lines for the detection of respiratory viruses. J. Clin. Virol. 22:101-110. - PubMed
    1. Bellei, N., D. Benfica, A. H. Perosa, R. Carlucci, M. Barros, and C. Granato. 2003. Evaluation of a rapid test (QuickVue) compared with the shell vial assay for detection of influenza virus clearance after antiviral treatment. J. Virol. Methods 109:85-88. - PubMed
    1. Bonner, A. B., K. W. Monroe, L. I. Talley, A. E. Klasner, and D. W. Kimberlin. 2003. Impact of the rapid diagnosis of influenza on physician decision-making and patient management in the pediatric emergency department: results of a randomized, prospective, controlled trial. Pediatrics 112:363-367. - PubMed
    1. Cazacu, A. C., J. Greer, M. Taherivand, and G. J. Demmler. 2003. Comparison of lateral-flow immunoassay and enzyme immunoassay with viral culture for rapid detection of influenza virus in nasal wash specimens from children. J. Clin. Microbiol. 41:2132-2134. - PMC - PubMed

Publication types

MeSH terms