Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Aug;35(8):1882-7.
doi: 10.1097/01.CCM.0000275268.94404.43.

Arterial carboxyhemoglobin level and outcome in critically ill patients

Affiliations

Arterial carboxyhemoglobin level and outcome in critically ill patients

Daniel D Melley et al. Crit Care Med. 2007 Aug.

Abstract

Objective: Arterial carboxyhemoglobin is elevated in patients with critical illness. It is an indicator of the endogenous production of carbon monoxide by the enzyme heme oxygenase, which modulates the response to oxidant stress. The objective was to explore the hypothesis that arterial carboxyhemoglobin level is associated with inflammation and survival in patients requiring cardiothoracic intensive care.

Design: Prospective, observational study.

Setting: A cardiothoracic intensive care unit.

Patients: All patients admitted over a 15-month period.

Interventions: None.

Measurements and main results: Arterial carboxyhemoglobin, bilirubin, and standard biochemical, hematologic, and physiologic markers of inflammation were measured in 1,267 patients. Associations were sought between levels of arterial carboxyhemoglobin, markers of the inflammatory response, and clinical outcome. Intensive care unit mortality was associated with lower minimum and greater maximal carboxyhemoglobin levels (p < .0001 and p < .001, respectively). After adjustment for age, gender, illness severity, and other relevant variables, a lower minimum arterial carboxyhemoglobin was associated with an increased risk of death from all causes (odds risk of death, 0.391; 95% confidence interval, 0.190-0.807; p = .011). Arterial carboxyhemoglobin correlated with markers of the inflammatory response.

Conclusions: Both low minimum and high maximum levels of arterial carboxyhemoglobin were associated with increased intensive care mortality. Although the heme oxygenase system is protective, excessive induction may be deleterious. This suggests that there may be an optimal range for heme oxygenase-1 induction.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources