Tibiofemoral force following total knee arthroplasty: comparison of four prosthesis designs in vitro
- PMID: 17568418
- DOI: 10.1002/jor.20438
Tibiofemoral force following total knee arthroplasty: comparison of four prosthesis designs in vitro
Erratum in
- J Orthop Res. 2008 Apr;26(4):578
Abstract
Despite ongoing evolution in total knee arthroplasty (TKA) prosthesis design, restricted flexion continues to be common postoperatively. Compressive tibiofemoral force during flexion is generated through the interaction between soft tissues and prosthesis geometry. In this study, we compared the compressive tibiofemoral force in vitro of four commonly used prostheses: fixed-bearing PCL (posterior cruciate ligament)-retaining (PFC), mobile-bearing posterior-stabilized (PS), posterior-stabilized with a High Flex femoral component (HF), and mobile-bearing PCL-sacrificing (LCS). Fourteen fresh-frozen cadaver knee joints were tested in a passive motion rig, and tibiofemoral force measured using a modified tibial baseplate instrumented with six load cells. The implants without posterior stabilization displayed an exponential increase in force after 90 degrees of flexion, while PS implants maintained low force throughout the range of motion. The fixed-bearing PFC prosthesis displayed the highest peak force (214 +/- 68 N at 150 degrees flexion). Sacrifice of the PCL decreased the peak force to a level comparable with the LCS implant. The use of a PCL-substituting post and cam system reduced the peak force up to 78%, irrespective of whether it was a high-flex or a standard PS knee. However, other factors such as preoperative range of motion, knee joint kinematics, soft tissue impingement, and implantation technique play a role in postoperative knee function. The present study suggests that a posterior-stabilized TKA design might be advantageous in reducing soft tissue tension in deep flexion. Further research is necessary to fully understand all factors affecting knee flexion after TKA.
(c) 2007 Orthopaedic Research Society.
Similar articles
-
[In vitro investigation of posterior cruciate ligament strain following total knee arthroplasty].Z Orthop Ihre Grenzgeb. 2006 Mar-Apr;144(2):164-71. doi: 10.1055/s-2006-921540. Z Orthop Ihre Grenzgeb. 2006. PMID: 16625446 German.
-
Dynamic in vitro measurement of posterior cruciate ligament load and tibiofemoral stress after TKA in dependence on tibiofemoral slope.Clin Biomech (Bristol). 2006 Jun;21(5):525-32. doi: 10.1016/j.clinbiomech.2005.12.019. Epub 2006 Feb 21. Clin Biomech (Bristol). 2006. PMID: 16494980
-
Sensitivity of knee soft-tissues to surgical technique in total knee arthroplasty.Knee. 2011 Jun;18(3):180-4. doi: 10.1016/j.knee.2010.05.005. Epub 2010 Jun 12. Knee. 2011. PMID: 20542437
-
Influence of posterior condylar offset on knee flexion after cruciate-sacrificing mobile-bearing total knee replacement: a prospective analysis of 410 consecutive cases.Knee. 2010 Dec;17(6):375-80. doi: 10.1016/j.knee.2009.11.001. Epub 2009 Dec 2. Knee. 2010. PMID: 19954982 Review.
-
Optimizing flexion after total knee arthroplasty: advances in prosthetic design.Clin Orthop Relat Res. 2003 Nov;(416):167-73. doi: 10.1097/01.blo.0000081937.75404.ee. Clin Orthop Relat Res. 2003. PMID: 14646757 Review.
Cited by
-
Intraoperative joint gaps affect postoperative range of motion in TKAs with posterior-stabilized prostheses.Clin Orthop Relat Res. 2013 Apr;471(4):1326-33. doi: 10.1007/s11999-012-2755-z. Epub 2012 Dec 19. Clin Orthop Relat Res. 2013. PMID: 23250854 Free PMC article.
-
Clinical outcome of increased flexion gap after total knee arthroplasty. Can controlled gap imbalance improve knee flexion?Knee Surg Sports Traumatol Arthrosc. 2017 Jun;25(6):1705-1711. doi: 10.1007/s00167-016-4009-1. Epub 2016 Feb 4. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 26846656 Clinical Trial.
-
Dislocation after Posterior Stabilized Primary Total Knee Replacement: A Rare Complication in Four Cases.Case Rep Orthop. 2021 Oct 13;2021:9935401. doi: 10.1155/2021/9935401. eCollection 2021. Case Rep Orthop. 2021. PMID: 34691797 Free PMC article.
-
In vivo contact kinematics and contact forces of the knee after total knee arthroplasty during dynamic weight-bearing activities.J Biomech. 2008 Jul 19;41(10):2159-68. doi: 10.1016/j.jbiomech.2008.04.021. Epub 2008 Jun 5. J Biomech. 2008. PMID: 18538328 Free PMC article.
-
Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study.J Exp Orthop. 2022 Feb 15;9(1):17. doi: 10.1186/s40634-022-00456-0. J Exp Orthop. 2022. PMID: 35169966 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous