Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty
- PMID: 17570282
- DOI: 10.1016/j.arth.2007.01.019
Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty
Abstract
Tapered cementless femoral fixation provides a reliable option for routine primary total hip arthroplasty (THA). The use of hydroxyapatite (HA)-coated stems is increasing as a result of mounting evidence that HA may improve the reliability of bone osseointegration and improve overall THA outcomes. These trends are based on a growing body of literature that supports both the theoretical and clinical rationale of this approach. There is solid clinical evidence that the combination of tapered geometry with an HA coating increases the likelihood of reliable femoral fixation. A comprehensive review of this literature evaluating the clinical use of cementless femoral components that use an HA coating is presented, and reveals that HA-coated stems have significantly improved proximal femoral fixation with less stress shielding and superior osseous remodeling. Although these advantages have not been shown to significantly increase long-term durability, there is sufficient data to support the routine use of HA-coated, tapered cementless femoral stems in THA.
Similar articles
-
The use of a hydroxyapatite-coated primary stem in revision total hip arthroplasty.J Arthroplasty. 2006 Jan;21(1):64-71. doi: 10.1016/j.arth.2004.11.013. J Arthroplasty. 2006. PMID: 16446187
-
[Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].Acta Chir Orthop Traumatol Cech. 2009 Jun;76(3):172-8. Acta Chir Orthop Traumatol Cech. 2009. PMID: 19595277 Czech.
-
Bone remodeling in proximal HA-coated versus uncoated cementless SL-Plus((R)) femoral components: a 5-year follow-up study.Arch Orthop Trauma Surg. 2010 Jul;130(7):921-6. doi: 10.1007/s00402-009-1040-4. Epub 2010 Jan 5. Arch Orthop Trauma Surg. 2010. PMID: 20049601
-
Cementless femoral design concerns. Rationale for extensive porous coating.Clin Orthop Relat Res. 1998 Oct;(355):189-99. Clin Orthop Relat Res. 1998. PMID: 9917604 Review.
-
Extensively coated cementless femoral components in revision total hip arthoplasty: an update.Surg Technol Int. 2005;14:265-74. Surg Technol Int. 2005. PMID: 16525982 Review.
Cited by
-
The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation.Arch Med Sci. 2012 May 9;8(2):199-208. doi: 10.5114/aoms.2012.28545. Arch Med Sci. 2012. PMID: 22661990 Free PMC article.
-
A concise minimum eight year follow-up of proximally porous-coated tapered titanium femoral stem in primary total hip arthroplasty.Int Orthop. 2012 Aug;36(8):1561-5. doi: 10.1007/s00264-012-1515-8. Epub 2012 Mar 14. Int Orthop. 2012. PMID: 22410972 Free PMC article.
-
Results of a hydroxyapatite-coated femoral stem (Corail) in Chinese: a minimum 10-year follow-up.Springerplus. 2016 Nov 15;5(1):1983. doi: 10.1186/s40064-016-3656-5. eCollection 2016. Springerplus. 2016. PMID: 27917354 Free PMC article.
-
Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.Clin Orthop Relat Res. 2009 Nov;467(11):2872-9. doi: 10.1007/s11999-009-0796-8. Epub 2009 Mar 28. Clin Orthop Relat Res. 2009. PMID: 19330391 Free PMC article. Clinical Trial.
-
Survival outcomes of cemented compared to uncemented stems in primary total hip replacement.World J Orthop. 2014 Nov 18;5(5):591-6. doi: 10.5312/wjo.v5.i5.591. eCollection 2014 Nov 18. World J Orthop. 2014. PMID: 25405087 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources