Purpose: To test the feasibility of first-pass contrast-enhanced myocardial perfusion imaging at 3 Tesla and to evaluate the change in perfusion index between normal, remote and ischemic myocardium, we obtained perfusion index from healthy subjects and patients with coronary artery stenosis.
Materials and methods: First-pass contrast-enhanced perfusion imaging was performed on 12 patients and 32 age-matched healthy subjects in both rest and dipyridamole-induced stress states. After bolus injection of contrast agent, Gd-DTPA with dose of 0.025 mmol/kg body weight and injection time of 1.5 s, three short-axis images from apex to base of the left ventricle (LV) were acquired for 80 cardiac cycles using saturation recovery turbo FLASH sequence. The maximal upslope (Upslope) was derived from the signal-time curves of the LV cavity and myocardium to measure myocardial perfusion. Within 72 hours after cardiovascular magnetic resonance examination, patients received coronary angiography, and the results were correlated with cardiovascular magnetic resonance results.
Results: Using our protocol of contrast agent administration, sufficient perfusion contrast was obtained without susceptibility-induced signal drop-out at the interface between LV cavity and the myocardium. In healthy volunteers, Upslope showed no dependence on myocardial segments or coronary territories. Upslope increased significantly from rest to stress in normal myocardium (0.09 +/- 0.03 vs. 0.16 +/- 0.05, p < 0.001) and remote myocardium (0.09 +/- 0.03 vs. 0.13 +/- 0.03, p < 0.001), whereas in ischemic myocardium the change was insignificant (0.11 +/- 0.03 vs. 0.10 +/- 0.04, p = ns). This resulted in significant difference in the ratio of Upslope at stress to that at rest, representing myocardial perfusion reserve, between ischemic and non-ischemic myocardium (0.96 +/- 0.41 vs. 1.71 +/- 0.42, p < 0.001 for ischemic vs. normal myocardium; 0.96 +/- 0.41 vs. 1.59 +/- 0.40, p < 0.001 for ischemic vs. remote myocardium).
Conclusions: First-pass gadolinium-enhanced myocardial perfusion imaging at 3 Tesla is feasible. The Upslope ratio can differentiate ischemic from non-ischemic myocardium.
Similar articles
-
[Myocardial microcirculation in humans--new approaches using MRI].Herz. 2003 Mar;28(2):74-81. doi: 10.1007/s00059-003-2451-6. Herz. 2003. PMID: 12669220 German.
-
Contrast-dose relation in first-pass myocardial MR perfusion imaging.J Magn Reson Imaging. 2007 Jun;25(6):1131-5. doi: 10.1002/jmri.20910. J Magn Reson Imaging. 2007. PMID: 17520736
-
Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography.Circ Cardiovasc Imaging. 2010 Jan;3(1):32-40. doi: 10.1161/CIRCIMAGING.109.860148. Epub 2009 Nov 17. Circ Cardiovasc Imaging. 2010. PMID: 19920032
-
Magnetic resonance imaging for ischemic heart disease.J Magn Reson Imaging. 2007 Jul;26(1):3-13. doi: 10.1002/jmri.20976. J Magn Reson Imaging. 2007. PMID: 17659549 Review.
-
Concepts of myocardial perfusion imaging in magnetic resonance imaging.Magn Reson Q. 1994 Dec;10(4):249-86. Magn Reson Q. 1994. PMID: 7873354 Review.
Cited by
-
The role of first-pass perfusion deficit in the detection of cardiac subendocardial manifestation in patients with autoimmune vasculitis.Rheumatol Int. 2013 Jan;33(1):29-35. doi: 10.1007/s00296-011-2310-3. Epub 2012 Jan 3. Rheumatol Int. 2013. PMID: 22212409
-
Collateral circulation formation determines the characteristic profiles of contrast-enhanced MRI in the infarcted myocardium of pigs.Acta Pharmacol Sin. 2015 Apr;36(4):463-72. doi: 10.1038/aps.2014.158. Epub 2015 Mar 23. Acta Pharmacol Sin. 2015. PMID: 25832427 Free PMC article.
-
MRI and CT in the diagnosis of coronary artery disease: indications and applications.Insights Imaging. 2011 Feb;2(1):9-24. doi: 10.1007/s13244-010-0049-0. Epub 2010 Nov 23. Insights Imaging. 2011. PMID: 22347932 Free PMC article.
-
A spatially-distributed computational model to quantify behaviour of contrast agents in MR perfusion imaging.Med Image Anal. 2014 Oct;18(7):1200-16. doi: 10.1016/j.media.2014.07.002. Epub 2014 Jul 18. Med Image Anal. 2014. PMID: 25103922 Free PMC article.
-
[3 tesla magnetic resonance imaging in children and adults with congenital heart disease].Radiologe. 2010 Sep;50(9):799-806, 808. doi: 10.1007/s00117-010-2025-6. Radiologe. 2010. PMID: 20617299 German.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Miscellaneous