Real time myocardial contrast echocardiography during supine bicycle stress and continuous infusion of contrast agent. Cutoff values for myocardial contrast replenishment discriminating abnormal myocardial perfusion
- PMID: 17584204
- DOI: 10.1111/j.1540-8175.2007.00442.x
Real time myocardial contrast echocardiography during supine bicycle stress and continuous infusion of contrast agent. Cutoff values for myocardial contrast replenishment discriminating abnormal myocardial perfusion
Abstract
Background: Myocardial contrast echocardiography (MCE) is a new imaging modality for diagnosing coronary artery disease (CAD).
Objective: The aim of our study was to evaluate feasibility of qualitative myocardial contrast replenishment (RP) assessment during supine bicycle stress MCE and find out cutoff values for such analysis, which could allow accurate detection of CAD.
Methods: Forty-four consecutive patients, scheduled for coronary angiography (CA) underwent supine bicycle stress two-dimensional echocardiography (2DE). During the same session, MCE was performed at peak stress and post stress. Ultrasound contrast agent (SonoVue) was administered in continuous mode using an infusion pump (BR-INF 100, Bracco Research). Seventeen-segment model of left ventricle was used in analysis. MCE was assessed off-line in terms of myocardial contrast opacification and RP. RP was evaluated on the basis of the number of cardiac cycles required to refill the segment with contrast after its prior destruction with high-power frames. Determination of cutoff values for RP assessment was performed by means of reference intervals and receiver operating characteristic analysis. Quantitative CA was carried out using CAAS system.
Results: MCE could be assessed in 42 patients. CA revealed CAD in 25 patients. Calculated cutoff values for RP-analysis (peak-stress RP >3 cardiac cycles and difference between peak stress and post stress RP >0 cardiac cycles) provided sensitive (88%) and accurate (88%) detection of CAD. Sensitivity and accuracy of 2DE were 76% and 79%, respectively.
Conclusions: Qualitative RP-analysis based on the number of cardiac cycles required to refill myocardium with contrast is feasible during supine bicycle stress MCE and enables accurate detection of CAD.
Similar articles
-
Diagnosis of ischaemic heart disease by myocardial contrast echocardiography during supine bicycle stress.Kardiol Pol. 2006 Apr;64(4):355-61; discussion 362-3. Kardiol Pol. 2006. PMID: 16699976 Clinical Trial. English, Polish.
-
Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.J Am Coll Cardiol. 2013 Oct 8;62(15):1353-61. doi: 10.1016/j.jacc.2013.04.082. Epub 2013 Jun 13. J Am Coll Cardiol. 2013. PMID: 23770168 Clinical Trial.
-
Quantitative myocardial contrast supine bicycle stress echocardiography for detection of coronary artery disease.Echocardiography. 2013 Apr;30(4):392-400. doi: 10.1111/echo.12064. Epub 2012 Dec 18. Echocardiography. 2013. PMID: 23252652
-
[The value of contrast in stress echocardiography].Arch Mal Coeur Vaiss. 2004 Jan;97(1):46-52. Arch Mal Coeur Vaiss. 2004. PMID: 15002711 Review. French.
-
Advances in myocardial contrast echocardiography and the role of adenosine stress.Am J Cardiol. 2004 Jul 22;94(2A):12D-17D; discussion 17D-18D. doi: 10.1016/j.amjcard.2004.04.011. Am J Cardiol. 2004. PMID: 15261126 Review.
Cited by
-
Stress echocardiography with contrast for the diagnosis of coronary artery disease: an evidence-based analysis.Ont Health Technol Assess Ser. 2010;10(10):1-59. Epub 2010 Jun 1. Ont Health Technol Assess Ser. 2010. PMID: 23074387 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous